Skip to main content

ORIGINAL RESEARCH article

Front. Microbiol., 03 August 2016
Sec. Food Microbiology
This article is part of the Research Topic Quantification of pathogens by molecular methods View all 15 articles

Quantification of Hepatitis E Virus in Naturally-Contaminated Pig Liver Products

\r\nSandra Martin-LatilSandra Martin-LatilCatherine Hennechart-ColletteCatherine Hennechart-ColletteSabine DelannoySabine DelannoyLaurent GuillierLaurent GuillierPatrick FachPatrick FachSylvie Perelle*Sylvie Perelle*
  • Université Paris Est (ANSES), Laboratory for Food Safety, Maisons-Alfort, France

Hepatitis E virus (HEV), the cause of self-limiting acute hepatitis in humans, is widespread and endemic in many parts of the world. The foodborne transmission of HEV has become of concern due to the identification of undercooked pork products as a risk factor for infection. Foodborne enteric viruses are conventionally processed by quantitative RT-PCR (RT-qPCR), which gives sensitive and quantitative detection results. Recently, digital PCR (dPCR) has been described as a novel approach to genome quantification with no need for a standard curve. The performance of microfluidic digital RT-PCR (RT-dPCR) was compared to RT-qPCR when detecting HEV in pig liver products. The sensitivity of the RT-dPCR assay was similar to that of RT-qPCR, and quantitative data obtained by both detection methods were not significantly different for almost all samples. This absolute quantification approach may be useful for standardizing quantification of HEV in food samples and may be extended to quantifying other human pathogens in food samples.

Introduction

Hepatitis E virus (HEV) is a small non-enveloped single-stranded positive-sense RNA virus belonging to the Hepeviridae family (Emerson et al., 2004). HEV infection is generally asympto matic and is most commonly manifested as a self-limiting acute hepatitis in immunocompetent individuals (Aggarwal and Jameel, 2011).

The four genotypes able to infect humans have been recently classified into the Orthohepevirus A species within the Orthohepevirus genus (Smith et al., 2014). Genotypes 1 and 2 only infect humans, and are restricted to specific geographical areas (i.e., Asia, Africa, and Mexico). They often spread among the population as waterborne open epidemic outbreaks. On the contrary, genotypes 3 and 4 have also been isolated from different animal species and their zoonotic transmission is responsible for sporadic human cases, worldwide in the case of HEV genotype 3, and mainly in Asia for HEV genotype 4. Most episodes of zoonotic transmission associated with genotypes 3 and 4 are foodborne and have been linked to the ingestion of raw or undercooked meat, liver, and liver sausages from infected wild or domestic animals (boar, pigs, and deer) (Tei et al., 2003; Yazaki et al., 2003; Masuda et al., 2005; Deest et al., 2007; Colson et al., 2010). The presence of HEV in pig liver at grocery stores has been confirmed in the USA (Feagins et al., 2007), Japan (Okano et al., 2014), and various European countries, namely the Netherlands (Bouwknegt et al., 2007), the UK (Berto et al., 2012), Germany (Wenzel et al., 2011), Italy, Spain, and the Czech Republic (Di Bartolo et al., 2012). In France, foodstuffs containing raw pig liver were found to be contaminated by HEV (Colson et al., 2010; Martin-Latil et al., 2014).

A detection method developed to assess the risk related to the presence of HEV in food was found to give satisfactory performance, particularly in the framework of a French monitoring program (Martin-Latil et al., 2014). This method includes a virus concentration step by PEG followed by viral RNA extraction and subsequent detection by quantitative real-time RT-PCR (RT-qPCR).

To date, real-time RT-PCR has been one of the most promising detection methods due to its sensitivity, specificity and speed. The RT-qPCR assay has become the gold standard for quantitative viral diagnosis (Gunson et al., 2006). However, viral genome quantification is based on a standard curve which requires careful calibration and consistent source material. Therefore, due to differences in standard curve construction and potential analysis subjectivity, this relative quantitation approach has limitations, and may lead to inter-laboratory variations (Bustin and Nolan, 2004).

Digital PCR (dPCR) is a specific and sensitive endpoint absolute quantification approach that can determine target copy numbers without the need for a standard curve, thus leading to potentially more accurate and more precise quantification of nucleic acids. The principle of digital PCR relies on the partitioning of samples into multiple separate reactions that can be accomplished by generating micro-droplets or through the use of micro-fluidic chips. The signal in dPCR is measured after completing amplification, and the absolute number of target nucleic acid molecules in the sample is directly calculated from the ratio of positive to total partitions using binomial Poisson statistics (Dube et al., 2008; Pinheiro et al., 2012). This approach may also reduce the difficulty in quantifying viruses in the presence of inhibitors linked to matrix-type components analyzed in food or environmental virology (Racki et al., 2014).

In this study, a microfluidic digital RT-PCR chip with a 48-sample capacity was explored to determine the potential of this new concept of nucleic acid quantification in the field of food virology. The two most commonly process control viruses, Mengovirus, and murine norovirus (MNV-1) were used separately to check sample processing and an external amplification control (HEV transcribed RNA) to evaluate RT-PCR inhibition.

The reference RT-qPCR method was compared to the microfluidic digital RT-PCR (RT-dPCR) assay in terms of ability and sensitivity for detecting and quantifying HEV RNA genomes from naturally contaminated figatelli and pig liver sausages previously collected in the framework of a French surveillance plan.

Materials and Methods

Food Samples Containing Pig Liver

Food samples (figatelli and pig liver sausages) were collected within the framework of an official national surveillance plan organized by the French Ministry of Agriculture, Food and Forestry in 2011, according to EC Directive 2003/99/EC (2003) and EC Regulation 882/2004 (2004). Of the 400 samples qualitatively analyzed to detect HEV (Pavio et al., 2014), 70 were also quantitatively analyzed (Martin-Latil et al., 2014) and kept at -80°C. Six figatelli and six pig liver sausages previously found positive for the presence of HEV genomes were selected for this study according to their HEV contamination level. One figatellu and one pig liver sausage in which HEV genomes were not detected were used as negative samples.

Process Control Viruses

The two most commonly used process controls, Mengovirus, or murine norovirus (MNV-1) were added before processing to monitor the whole viral extraction method. Dr. H. Virgin from Washington University (Saint Louis, MO, USA) supplied the ANSES Fougères Laboratory (Fougères, France) with the MNV-1 (CW1 strain), which was propagated in a mouse leukemic monocyte macrophage (RAW 264.7, ATCC TIB-71) cell line (Cannon et al., 2006). RAW 264.7 was grown at 37°C in an atmosphere containing 5% CO2 in DMEM supplemented with GlutaMAXTM, 1% non-essential amino acids and 10% fetal bovine serum (Life Technologies, Saint Aubin, France). The extracted RNA was quantified by measuring absorbance at 260/280 nm with a spectrophotometer (NanoDrop ND-1000) using the formula Copies = [weight (g) × 6.023 × 1023]/[size (bp) × 320.5], and its amplification was checked by RT-qPCR. Based on this approach, the production stock of MNV-1 had titres of approximately 1.36 × 1012 genome copies/mL.

A non-virulent mutant strain of mengovirus (vMC0 strain) (kindly provided by Albert Bosch, Department of Microbiology, Enteric Virus Group, University of Barcelona, Spain) was grown on HeLa cells (ATCC, CCL-2TM) as described by Costafreda et al. (2006). HeLa cells were grown at 37°C in an atmosphere containing 5% CO2 in Minimum Essential Media GlutamaxTM (MEM), 1% non-essential amino acids and 10% fetal bovine serum (Life Technologies). The extracted RNA was quantified by measuring absorbance at 260/280 nm with the NanoDrop ND-1000 using the formula Copies = [weight (g) × 6.023 × 1023]/[size (bp) × 320.5], and its amplification was checked by RT-qPCR. Based on this approach, the production stock of mengovirus had titres of approximately 6.68 × 1011 copies/mL.

External Control (EC) RNA

An in vitro RNA transcript of HEV was used as an external control (EC) to monitor RT-PCR inhibition in RNA extracts.

The HEV cDNA corresponding to positions 5301-5371 of the genomic sequence (AB097812) was cloned in pGEM-T Easy Vector (Promega, Charbonnières-les-Bains, France) and propagated in E. coli One Shot® TOP10F’ (Invitrogen, Cergy Pontoise, France). High-quality plasmid DNA containing this HEV region was purified using a QIAGEN Plasmid Midi kit (Qiagen, Courtaboeuf, France) according to the manufacturer’s protocol. The plasmid DNA was then digested with SpeI (Invitrogen) and transcripts were obtained using the MEGAscript® kit (Ambion, Fisher Scientific, Illkirch, France) according to the manufacturer’s protocol. Synthesized RNA was treated once with RNase-Free DNase according to the manufacturer’s protocol to remove the DNA template following transcription, and purified using the RNeasy Mini kit (Qiagen). The synthesized RNA was confirmed with RT-qPCR and quantified by measuring absorbance at 260/280 nm with the NanoDrop ND-1000 (Thermoscientific, Courtaboeuf, France) using the formula Copies = [weight (g) × 6.023 × 1023]/[size (bp) × 320.5]. Aliquots of 20 μL with 108 genome copies/μl were kept frozen at -80°C for later use as external amplification controls (EAC). One microlitre of EC RNA was added to an aliquot of RNA extract and tested using RT-qPCR. By comparing this result with the result of the EC RNA in the absence of an RNA extract, it is possible to determine the level of RT-PCR inhibition in each sample under test.

Viral RNA Used as RNA Standards for HEV Quantification by RT-qPCR

Clarified HEV genotype 3f suspension was obtained from fecal samples of infected swine provided by ANSES’s Maisons-Alfort Laboratory for Animal Health. Pig HEV contaminated stools were obtained at Anses (Ploufragan) according to the animal welfare experimentation agreement (registration number C-22-745-1). The partial sequence was previously deposited with GenBank accession number JF718793.

The fecal sample was suspended in 10 mM Phosphate Buffered Saline of pH 7.4 to obtain a final 10% suspension (w/v), and then vortexed and centrifuged at 4000 g for 20 min at 4°C. The clarified fecal suspension was processed by the NucliSens® easyMAGTM Platform for viral genome extraction. The genomic titre was determined by RT-qPCR using an RT-qPCR standard curve obtained with the 10-fold diluted in vitro RNA transcripts. Viral RNA stock had a titre of approximately 1.75 × 106 genome copies /mL. Aliquots were stored at -80°C for later use as RNA standards for HEV quantification by RT-qPCR.

Sample Processing for Virus Recovery and Viral RNA Extraction

All the food samples were separated into 3 g portions and placed in a 400 mL polypropylene bag containing a filter compartment. To control losses of target virus which can occur at several stages during food sample analysis, a defined amount of process control virus—either 1.36 × 1010 genome copies of MNV-1 or 6.68 × 106 genome copies of mengovirus—was inoculated on food samples (figatelli and pig liver sausages) (Martin-Latil et al., 2014; Hennechart-Collette et al., 2015). The inoculum was 100 μL of a dilution in diethylpyrocarbonate (DEPC)-treated water (Life Technologies) of the MNV-1 or mengovirus stock suspension. This was the earliest opportunity prior to virus extraction to check extraction efficiency. Uninoculated samples were used as a negative control for the process control virus.

Each food sample (3 g) was homogenized in 30 mL of distilled water using a Stomacher apparatus (Fisher Bioblock Scientific, Illkirch, France) at a normal velocity for 2 min. After an incubation of 10 min at room temperature with constant shaking, the filtrate was transferred to a 50-mL centrifuge tube and centrifuged at 8,000g for 15 min at 4°C to be clarified (removal of particulate debris). The decanted supernatant was supplemented with 10% (wt/vol) polyethylene glycol (PEG) 6000 (Sigma-Aldrich, Saint-Quentin Fallavier, France) and 0.3 M NaCl, and was then incubated for 2 h at 4°C. Viruses were concentrated by centrifugation of the solution at 8,000g for 30 min at 4°C. The supernatant was discarded and an additional centrifugation was performed at 8,000g for 5 min at 4°C to compact the pellet. This viral pellet was resuspended with 3 mL NucliSens® easyMAGTM lysis buffer (BioMérieux, Marcy l’Etoile, France) and lysed viral particles were processed on the NucliSens® easyMAGTM Platform (BioMérieux) for total nucleic acid extraction by the “off-board Specific A” protocol according to the manufacturer’s instructions. Lastly, nucleic acids were eluted in 70 μL of elution buffer, aliquoted and stored at -80°C.

Each experiment set, from spiking to RNA extraction, comprised seven figatelli and seven pig liver sausages and was performed 3 times. The same RNA extract (undiluted and 10-fold diluted) was analyzed in duplicate with the RT-qPCR assay and the digital RT-dPCR (RT-dPCR) to detect and quantify HEV genomes.

Primers and Probes

The sequence of primer pairs and TaqMan probes used for HEV (viral genome and external control) and MNV-1 were those previously described (Martin-Latil et al., 2012; Martin-Latil et al., 2014). For HEV, the primers and TaqMan® probe targeting the ORF2/ORF3 overlapping region were: 5′-CGGTGGTTTCTGGGGTGAC-3′ for the sense primer (HEV-5260-F), 5′-AGGGGTTGGTTGGATGAATATAG-3′ for the anti sense primer (HEV-5330-R) and 5′-ROX-GGGTTGATTCTCA GCCCTTCGC – BHQ2-3′ for the TaqMan probe (HEV-5280-T). For MNV, the sense primer (MNV-3193-F) was 5′-CCGCCATGGTCCTGGAGAATG-3′, the antisense primer (MNV-3308-R) was 5′-GCACAACGGCACTACCAATCTTG-3′ and the TaqMan probe (MNV-3227-T) was 5′-FAM–CGTCGTCGCCTCGGTCCTTGTCAA-BHQ1-3′.

For mengovirus, the sense primer (Mengo 110) was 5′-GCGGGTCCTGCCGAAAGT-3′, the antisense primer (Mengo 209) was 5′-GAAGTAACATATAGACAGACGCACAC-3′ and the TaqMan probe (Mengo 147) was 5′-FAM- ATCACATTAC TGGCCGAAGC-BHQ1-3′ (Costafreda et al., 2006).

All the primers and probes were purchased from Eurofins (Les Ulis, France).

RT-qPCR Conditions on Bio-Rad’s CFX96

One-step RT-qPCR amplifications were performed on a CFX96TM real-time PCR detection system from Bio-Rad (Marnes-la-Coquette, France). Reactions were performed in a 25 μL reaction mixture containing 1X RNA UltraSenseTM master mix and 1.25 μL of RNA UltrasenseTM enzyme mix, which are components of the RNA UltraSenseTM One-Step Quantitative RT-PCR System (Life Technologies), 2 U RNAse inhibitor (Life Technologies), 5 μg of bovine serum albumin (Life Technologies), 600 nM (HEV-5260-F or MNV-1) or 500 nM (mengovirus) of forward primer, 600 nM (HEV-5330-R or MNV-1) or 900 nM (mengovirus) of reverse primer, 250 nM of probe (HEV-5280-T, MNV-1 or mengovirus) and 5 μL of RNA extract. Pure and 10-fold diluted RNA extracts obtained from each food sample were tested in duplicate. They were tested with and without the addition of 1 μL of 1.0 × 108 genome copies of EAC (synthesized HEV RNA). Positive controls containing RNA extracted from virus suspensions and a negative control containing all the reagents except the RNA template were included in each run.

The one-step RT-qPCR program was 60 min reverse transcription of RNA at 55°C, followed by a 5 min denaturation step at 95°C, and lastly 40 cycles of 15 s at 95°C, 1 min at 60°C and 1 min at 65°C. The fluorescence was recorded by the apparatus at the end of the elongation steps (1 min at 65°C) for each amplification cycle. All samples were characterized by a corresponding cycle threshold (Ct) value. Negative samples gave no Ct value. A standard curve for each target (HEV, MNV-1, and mengovirus) was generated from 10-fold dilutions in ultrapure water of the titrated clarified suspension stocks. The slopes (S) of the regression lines were used to calculate the amplification efficiency (E) of the RT-qPCR reactions according to the formula E = 10∣-1/s-1.

Quality Controls

Both the quality controls used to check the end-to-end viral extraction procedure and the presence of PCR inhibitors in RNA extracts, namely process control viruses and EAC, respectively, were analyzed using quantitative data obtained by RT-qPCR.

Extraction yields obtained for MNV-1 and mengovirus used as process controls were calculated with the following formula:

Number of viral genomes detected in 5 μL of undiluted RNA extract from tested samples/number of viral genomes detected in 5 μL of RNA extract from viral inoculum spiked on food samples X 100” (if 10-fold diluted RNA samples are used, multiply by 10 to correct for the dilution factor).

The recovery rates of the EAC were calculated with the following formula:

Quantity of EAC detected in 5 μL of RNA extracts from samples (undiluted or 10-fold diluted) / quantity of EAC detected in 5 μL of ultrapure water X 100.

RT-dPCR Conditions on Fluidigm’s BioMark System

RT-dPCR amplifications were performed on a Fluidigm BioMark System using qdPCR 37K IFC digital array microfluidic chips (South San Francisco, CA, USA). With its nanoscale valves and channels, the BioMark Integrated Fluidic Circuit (IFC) controller partitions each of the 48 samples premixed with PCR reagents into a panel of 770 PCR reaction chambers (i.e., 36,960 individual qPCR reactions on a digital array). By counting the number of positive reactions, the number of target molecules in each sample can be accurately estimated according to Poisson distribution.

Reactions were performed in a 10 μL reaction mixture containing 1× of RNA UltraSenseTM master mix, 1× ROX reference dye and 0.44 μL of RNA UltraSenseTM enzyme mix, which are components of the RNA UltraSenseTMOne-step Quantitative RT-PCR System (Life Technologies), 1× of 20× GE Sample Loading Reagent (BioMark), 2 U RNAse inhibitor (Life Technologies), 600 nM of HEV forward primer (HEV-5260-F), 600 nM of HEV reverse primer (HEV-5330-R), 250 nM of HEV probe (HEV-5280-T) and 5.8 μL of RNA extract. A positive control containing HEV RNA extracted from viral stocks, and a negative control containing all the reagents except the RNA template, were included in each run. Pure and 10-fold diluted RNA extracts obtained from each sample were tested in duplicate. Six out of the 10 μL of reaction mix were loaded onto the chip with the IFC controller MX, but 0.65 μL was effectively partitioned into the 770 chambers of one panel, including 0.38 μL of RNA extract.

The temperature–time program was the same as that described above for RT-qPCR: 1 h at 55°C for the RT reaction, 5 min at 95°C as a hot start, and 45 cycles of 15 s at 95°C for denaturation, 1 min at 60°C for annealing, and 1 min at 65°C for extension.

Statistical Analysis

All statistical analyses were performed with Statgraphics Centurion XV.II software.

One-way analysis of variance (ANOVA) was applied on EAC recovery rates to test (1) the effect of the type of food matrix (figatelli vs. pig liver sausages) and (2) the inter-assay variability among each of the food matrices.

The extraction yields obtained for MNV-1 were compared to those obtained for mengovirus through a one-way ANOVA according to the food matrix.

The influence of sub-sampling on HEV quantification was assessed by a one-way ANOVA for each food sample (six figatelli and six pig liver sausage samples) according to the detection method used (RT-qPCR vs. RT-dPCR). Both detection methods were then compared for HEV quantification through a one-way ANOVA.

The result of the ANOVA is a p value associated with the hypothesis that the means (EAC recovery rates, extraction yields or HEV genome copies) of all groups were the same.

Results

HEV Detection by RT-qPCR and Quality Controls

The RT-qPCR assay was used to detect HEV in figatelli and pig liver sausages and to assess both quality controls (EAC and process control virus).

Monitoring for RT-qPCR Inhibition in RNA Extracts

The EAC corresponding to the HEV RNA target was used to examine a potential inhibition of the HEV RT-qPCR assay in viral RNA extracts. The recovery rates of EAC in undiluted RNA extracts obtained from figatelli and pig liver sausages varied from 41.75 to 47.23% and from 56.44 to 84.73%, respectively (Table 1). These results showed that none of the samples showed significant evidence of inhibition. Nevertheless, statistical analysis showed that EAC recovery rates obtained in RNA extracts from pig liver sausages were significantly higher than those obtained in figatelli RNA extracts (ANOVA; p-value<10-4) (Figure 1), while they were not significantly different in samples belonging to the same food type (ANOVA; P = 0.9546 for figatelli; P = 0.3578 for pig liver sausages).

TABLE 1
www.frontiersin.org

TABLE 1. Hepatitis E virus (HEV) detection in figatelli and pig liver sausages by RT-qPCR.

FIGURE 1
www.frontiersin.org

FIGURE 1. Population marginal means with standard error of EAC recovery rates obtained in RNA extracts from figatelli and pig liver sausages. Two means are significantly different if their intervals are disjoint and are not significantly different if their intervals overlap.

Monitoring for Viral Extraction Efficiency

To check the end-to-end viral extraction procedure, 1.36 × 1010 genome copies of MNV-1 or 6.68 × 106 genome copies of mengovirus were added to the figatelli and pig liver sausage samples prior to their processing. The resulting extraction yields for MNV-1 and mengovirus from undiluted RNA extracts are reported in Table 1.

Murine norovirus-1 and mengovirus were consistently detected in all RNA extracts obtained from figatelli and pig liver sausages. In figatelli, the recovery rates obtained for MNV-1 and mengovirus ranged from 0.04 to 7.14% and from 1.40 to 22.11%, respectively. Statistical analysis showed that they were significantly higher for mengovirus than for MNV-1 (ANOVA; P-value = 0.0351) (Figure 2A). In the same way, the recovery rates obtained for mengovirus (5.25-25.50%) in pig liver sausages were significantly higher than those for MNV-1 (0.98-14.09%) (ANOVA; p-value = 0.0042) (Figure 2B). The results showed that recovery rates obtained for process control viruses were higher than 1% for seven figatellu subsamples spiked with MNV-1 and 19 subsamples spiked with mengovirus. Nevertheless, all figatellu subsamples (F1 to F6) tested positive to the presence of HEV (in at least one of the two HEV RT-qPCR reactions). The recovery rates of MNV-1 and mengovirus were higher than 1% for 12 out of 21 and 17 out of 21 pig liver sausage subsamples, respectively. HEV was detected in three and four pig liver sausage samples spiked with MNV-1 (S4 to S6) and mengovirus (S3 to S6), respectively, for all the subsamples.

FIGURE 2
www.frontiersin.org

FIGURE 2. Population marginal means with standard error of viral extraction yields (MNV-1 and mengovirus). (A) Figatelli. (B) Pig liver sausages. Two means are significantly different if their intervals are disjoint and are not significantly different if their intervals overlap.

Detection of HEV by RT-qPCR vs. RT-dPCR

HEV Quantification on Standard Materials Used for RT-qPCR Assays

Hepatitis E virus quantification was firstly assessed on serial dilutions of HEV RNA extracted from the clarified stool supernatants which were titrated by using OD and used as a standard for HEV quantification in food matrices by RT-qPCR. The RT-qPCR and RT-dPCR assays have a limit of detection of 13 HEV genome copies/μl (based on OD quantification).

The number of theoretical expected HEV genome copies within 0.38 μL of RNA effectively loaded in the digital plate was calculated from OD quantification. RT-dPCR detected from 21.0 to 37.4% of the expected input standard copy number (Table 2).

TABLE 2
www.frontiersin.org

TABLE 2. Hepatitis E virus quantification by RT-dPCR on standard materials used for RT-qPCR assays.

As a whole, both detection methods have similar sensitivity and absolute quantification by RT-dPCR is 3- to 5-fold lower than quantification by RT-qPCR using standards quantified by OD.

HEV Detection in Naturally Contaminated Figatelli and Pig Liver Sausage Samples

Hepatitis E virus detection in figatelli and pig liver sausages by RT-qPCR and RT-dPCR was compared in terms of the numbers of HEV-positive reactions and HEV quantification (Table 3).

TABLE 3
www.frontiersin.org

TABLE 3. Quantification of HEV in figatelli and pig liver sausages by RT-qPCR and RT-dPCR.

The difference between the detection methods (RT-qPCR vs. RT-dPCR) did not exceed one HEV-positive reaction except for one sample (F2). For five out of six samples of figatellu and one out of six samples of pig liver sausage, HEV was detected in only one more reaction with the RT-qPCR assay than with the RT-dPCR assay. Conversely, one more positive reaction for HEV was found by RT-dPCR for three out of six samples of pig liver sausage. The same number of HEV-positive reactions was found by both detection methods for two samples of pig liver sausage. As a whole, HEV could be detected by both methods at the same frequency.

To compare HEV quantification by both quantitative detection methods (RT-qPCR vs. RT-dPCR), the effect of sub-sampling was first evaluated through a one-way ANOVA for every figatellu and pig liver sausage according to the detection method used (RT-qPCR versus RT-dPCR).

For figatellu samples, the number of HEV genomes found by RT-qPCR and RT-dPCR varied significantly among subsamples (ANOVA; p < 0.05) except for sample F1 detected by RT-dPCR (ANOVA; p = 0.5217). For pig liver sausage samples, the number of HEV genomes found by RT-qPCR and RT-dPCR varied significantly among subsamples (ANOVA; p < 0.05) except for sample S2 detected by RT-qPCR (ANOVA; p = 0.4917). Therefore, RT-dPCR and RT-dPCR were compared by calculating the difference obtained for HEV quantification by both methods among subsamples and the mean of these differences are indicated for each sample in Table 3. The mean of differences in HEV quantification range from 0.08 to 0.45 for figatellu samples and from 0.11 to 0.76 for pig liver sausages. Moreover, the number of HEV genomes found by RT-qPCR was higher than that obtained by RT-dPCR except in the case of one pig liver sausage sample (S2). Nevertheless, the number of HEV genomes found by RT-dPCR was not significantly different from that obtained by RT-qPCR except in the case of two pig liver sausage samples (S5 (p < 0.0001); S6 (p < 0.0001)) as shown through a one-way ANOVA. Samples S5 and S6 had the highest differences in HEV quantification, with 0.63 and 0.76, respectively.

As a whole, the quantitative data obtained by both quantitative detection methods were not significantly different for almost all the samples.

Discussion

The foodborne transmission of HEV is mainly due to consumption of raw or undercooked liver, meat or sausages from infected animal reservoirs such as pigs or wild boar (Yugo and Meng, 2013). However, there is currently no standardized method for detecting HEV in such products. The previously described method, based on the detection of HEV genomes by RT-qPCR (Martin-Latil et al., 2014), proved its effectiveness for HEV detection in naturally contaminated figatelli and pig liver sausages. Nevertheless, there is a growing interest in novel digital PCR technologies that allow precise and absolute quantification of nucleic acids, which could be useful for detecting viruses in food. In this study, a microfluidic-based digital RT-PCR (RT-dPCR) was compared to conventional RT-qPCR for detecting and quantifying HEV genomes in figatelli and pig liver sausages.

The RT-dPCR assay was comparable to RT-qPCR in terms of sensitivity, and HEV was detected in food samples at the same frequency by both detection methods. The reaction conditions (reaction mixtures and cycling protocol) were identical, but the RNA volume for RT-dPCR was 13-fold lower than for conventional RT-qPCR. Despite this smaller input volume for RT-dPCR, a similar sensitivity was observed in line with previous authors (Dhoubhadel et al., 2014; Coudray-Meunier et al., 2015).

The absolute quantification of HEV obtained by RT-dPCR for naturally contaminated figatelli and pig liver sausages was not significantly different from that obtained by RT-qPCR except for two pig liver sausages with the highest levels of HEV contamination. Indeed, the dilution of RNA samples may be necessary for high amounts to ensure that the number of target molecules per panel falls within an optimal range (Dong et al., 2015). The absolute quantification of HEV by RT-dPCR in food samples was always slightly lower than HEV quantification by RT-qPCR. An overestimation of the quantification of nucleic acids by RT-qPCR had already been reported and attributed to the methods used to determine the concentration of standards (e.g., OD determination) (Henrich et al., 2012; Sanders et al., 2013; Coudray-Meunier et al., 2015). Many studies highlight the problem of using standards for nucleic acid quantification by RT-qPCR since they themselves can be a source of error. Therefore, digital PCR is a promising new technology with the advantage of quantifying nucleic acid without the need of a standard curve. It could also be helpful in smoothing out variations in the quantitative data obtained by different laboratories (Brunetto et al., 2014; Hayden et al., 2015). Recently, it has also been used for rotavirus quantification in different types of surface water (Racki et al., 2014).

The RT-dPCR assay could also detect and quantify HEV genomes in any of the food types tested by taking into account sub-sampling. Indeed, sub-sampling appeared to be an influencing factor when quantifying HEV in figatelli and pig liver sausages by RT-qPCR and RT-dPCR. These results suggest that the distribution of HEV within naturally contaminated samples was heterogeneous and/or that virus extraction from food varied between subsamples. Since virus detection in food relies on a multi-step procedure, differences between repeat experiments have already been reported according to the pathogenic virus and food matrix (Hennechart-Collette et al., 2015). In food virology, the inclusion of quality controls is crucial for checking the whole virus extraction procedure. A standard method for detecting and quantifying noroviruses and hepatitis A virus in food was recently published by the European Committee for Standardisation (CEN) (group CEN/TC275/WG6/TAG4 “Detection of viruses in food”) (ISO/TS 15216-1, 2013; ISO/TS 15216-2, 2013). Despite the absence of a standardized method for detecting HEV in food, we took into account recommendations indicated in ISO/TS15216 to correctly interpret assay results for HEV detection in figatelli and pig liver sausages. Therefore, the described method for detecting HEV included the use of process controls to determine the level of acceptability of recovery efficiency throughout the whole process and the use of an EAC to examine RT-qPCR inhibition.

Mengovirus and MNV-1 were tested as process control viruses and the recovery rates found in the present study were comparable to those determined by other studies (Baert et al., 2011; Martin-Latil et al., 2014; Hennechart-Collette et al., 2015). Furthermore, recovery rates obtained for mengovirus were significantly higher than those obtained for MNV-1 regardless of the food matrix, as previously reported (Hennechart-Collette et al., 2015).

Based on the ISO/TS 15216 standard, samples were considered valid for analysis when recovery of the process control was higher than 1%. Our results showed that the processing of almost all samples (36 out of 42 subsamples) could be validated by using mengovirus, whereas only half of the subsamples were validated with MNV-1 (19 out of 42). Nevertheless, HEV could be recovered from samples having mengovirus or MNV-1 extraction yields lower than 1% except for one pig liver sausage.

The efficiency of EAC was over 40% for both matrices. By taking into account the fact that EAC recovery rates may be over 25% as indicated in the ISO/TS, our results showed that none of the samples revealed significant evidence of RT-PCR inhibition. Nevertheless, the effect of PCR inhibitors on HEV detection was clearly dependent on the food matrix, since EAC recovery rates differed significantly between figatelli and pig liver sausages. Other food matrices considered at risk for HEV and showing high levels of PCR inhibition should be tested to evaluate the robustness of digital PCR in the presence of inhibitors. Indeed, digital PCR may offer an advantage over qPCR when dealing with inhibition-prone samples because individual micro-reactions mitigate the impact of inhibitors, as previously described by both ourselves and others (Dingle et al., 2013; Morisset et al., 2013; Nixon et al., 2014; Racki et al., 2014; Coudray-Meunier et al., 2015). Moreover, the price per sample for viral quantification was estimated at half the cost with RT-dPCR rather than RT-qPCR.

Conclusion

This study showed a novel application of microfluidic RT-dPCR and demonstrates its good potential for rapid, sensitive and accurate quantification of HEV genome in food matrices. As a result, RT-dPCR could be used as absolute quantification approach to routinely monitor enteric viruses in various food samples.

Author Contributions

Performed experiments: SM-L and CH-C. Analyzed data: SM-L and CH-C. Statistical study: S-ML and LG. Conceived and designed experiments: All authors. Wrote the paper and approved the final manuscript: All authors.

Funding

This work received financial support from ANSES.

Conflict of Interest Statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Acknowledgments

Samples were collected within the framework of an official national surveillance plan organized by the French Ministry of Agriculture, Food and Forestry in 2011, according to EC Regulation 882/2004 and EC Directive 2003/99/EC (2003), EC Regulation 882/2004 (2004). We wish to thank Julien Santolini, who organized the French HEV surveillance plan and Corinne Danan for her helpful advice and critical review of the manuscript. We would also like to thank Dr. Nicole Pavio for providing HEV-contaminated stools.

References

Aggarwal, R., and Jameel, S. (2011). Hepatitis E. Hepatology 54, 2218–2226. doi: 10.1002/hep.24674

CrossRef Full Text | Google Scholar

Baert, L., Mattison, K., Loisy-Hamon, F., Harlow, J., Martyres, A., Lebeau, B., et al. (2011). Review: norovirus prevalence in Belgian, Canadian and French fresh produce: a threat to human health? Int. J. Food Microbiol. 151, 261–269. doi: 10.1016/j.ijfoodmicro.2011.09.013

CrossRef Full Text | Google Scholar

Berto, A., Martelli, F., Grierson, S., and Banks, M. (2012). Hepatitis E virus in pork food chain, United Kingdom, 2009-2010. Emerg. Infect. Dis. 18, 1358–1360. doi: 10.3201/eid1808.111647

CrossRef Full Text | Google Scholar

Bouwknegt, M., Lodder-Verschoor, F., van der Poel, W. H., Rutjes, S. A., and de Roda Husman, A. M. (2007). Hepatitis E virus RNA in commercial porcine livers in the Netherlands. J. Food Prot. 70, 2889–2895.

Google Scholar

Brunetto, G. S., Massoud, R., Leibovitch, E. C., Caruso, B., Johnson, K., Ohayon, J., et al. (2014). Digital droplet PCR (ddPCR) for the precise quantification of human T-lymphotropic virus 1 proviral loads in peripheral blood and cerebrospinal fluid of HAM/TSP patients and identification of viral mutations. J. Neurovirol. 20, 341–351. doi: 10.1007/s13365-014-0249-3

CrossRef Full Text | Google Scholar

Bustin, S. A., and Nolan, T. (2004). Pitfalls of quantitative real-time reverse-transcription polymerase chain reaction. J. Biomol. Tech. 15, 155–166.

Google Scholar

Cannon, J. L., Papafragkou, E., Park, G. W., Osborne, J., Jaykus, L. A., and Vinje, J. (2006). Surrogates for the study of norovirus stability and inactivation in the environment: a comparison of murine norovirus and feline calicivirus. J. Food Prot. 69, 2761–2765.

Google Scholar

Colson, P., Borentain, P., Queyriaux, B., Kaba, M., Moal, V., Gallian, P., et al. (2010). Pig liver sausage as a source of hepatitis E virus transmission to humans. J. Infect. Dis. 202, 825–834. doi: 10.1086/655898

CrossRef Full Text | Google Scholar

Costafreda, M. I., Bosch, A., and Pinto, R. M. (2006). Development, evaluation, and standardization of a real-time TaqMan reverse transcription-PCR assay for quantification of hepatitis a virus in clinical and shellfish samples. Appl. Environ. Microbiol. 72, 3846–3855. doi: 10.1128/AEM.02660-05

CrossRef Full Text | Google Scholar

Coudray-Meunier, C., Fraisse, A., Martin-Latil, S., Guillier, L., Delannoy, S., Fach, P., et al. (2015). A comparative study of digital RT-PCR and RT-qPCR for quantification of Hepatitis a virus and Norovirus in lettuce and water samples. Int. J. Food Microbiol. 201, 17–26. doi: 10.1016/j.ijfoodmicro.2015.02.006

CrossRef Full Text | Google Scholar

Deest, G., Zehner, L., Nicand, E., Gaudy-Graffin, C., Goudeau, A., and Bacq, Y. (2007). Autochthonous hepatitis E in France and consumption of raw pig meat. Gastroenterol. Clin. Biol. 31, 1095–1097.

Google Scholar

Dhoubhadel, B. G., Yasunami, M., Yoshida, L. M., Thi, H. A., Thi, T. H., Thi, T. A., et al. (2014). A novel high-throughput method for molecular serotyping and serotype-specific quantification of Streptococcus pneumoniae using a nanofluidic real-time PCR system. J. Med. Microbiol. 63, 528–539. doi: 10.1099/jmm.0.071464-0

CrossRef Full Text | Google Scholar

Di Bartolo, I., Diez-Valcarce, M., Vasickova, P., Kralik, P., Hernandez, M., Angeloni, G., et al. (2012). Hepatitis E virus in pork production chain in Czech Republic, Italy, and Spain, 2010. Emerg. Infect. Dis. 18, 1282–1289. doi: 10.3201/eid1808.111783

CrossRef Full Text | Google Scholar

Dingle, T. C., Sedlak, R. H., Cook, L., and Jerome, K. R. (2013). Tolerance of droplet-digital PCR vs real-time quantitative PCR to inhibitory substances. Clin. Chem. 59, 1670–1672. doi: 10.1373/clinchem.2013.211045

CrossRef Full Text | Google Scholar

Dong, L., Meng, Y., Sui, Z., Wang, J., Wu, L., and Fu, B. (2015). Comparison of four digital PCR platforms for accurate quantification of DNA copy number of a certified plasmid DNA reference material. Sci. Rep. 25, 13174–13185. doi: 10.1038/srep13174

CrossRef Full Text | Google Scholar

Dube, S., Qin, J., and Ramakrishnan, R. (2008). Mathematical analysis of copy number variation in a DNA sample using digital PCR on a nanofluidic device. PLoS ONE 3:e2876. doi: 10.1371/journal.pone.0002876

CrossRef Full Text | Google Scholar

EC Directive 2003/99/EC (2003). Directive 2003/99/EC of the European Parliament and of the Council of 17 November 2003 on the monitoring of zoonoses and zoonotic agents, amending Council Decision 90/424/EEC and repealing Council Directive 92/117/EEC. Official J. L 325, 31–40.

Google Scholar

EC Regulation 882/2004 (2004). Regulation (EC) No 882/2004 of the European Parliament and of the Council of 29 April 2004 on official controls performed to ensure the verification of compliance with feed and food law, animal health and animal welfare rules. Official J. L 165, 30.4.

Google Scholar

Emerson, S., Anderson, D., Arankalle, V. A., Meng, X. J., Purdy, M., Schlauder, G. G., et al. (2004). “Hepevirus,” in Virus Taxonomy, VIIIth Report of the ICTV, eds C. M. Fauquet, M. A. Mayo, J. Maniloff, U. Desselberger, and L. A. Ball (London: Elsevier/Academic Press), 851–855.

Google Scholar

Feagins, A. R., Opriessnig, T., Guenette, D. K., Halbur, P. G., and Meng, X. J. (2007). Detection and characterization of infectious Hepatitis E virus from commercial pig livers sold in local grocery stores in the USA. J. Gen. Virol. 88, 912–917. doi: 10.1099/vir.0.82613-0

CrossRef Full Text | Google Scholar

Gunson, R. N., Collins, T. C., and Carman, W. F. (2006). Practical experience of high throughput real time PCR in the routine diagnostic virology setting. J. Clin. Virol. 35, 355–367. doi: 10.1016/j.jcv.2005.12.006

CrossRef Full Text | Google Scholar

Hayden, R. T., Gu, Z., Sam, S. S., Sun, Y., Tang, L., Pounds, S., et al. (2015). Comparative evaluation of three commercial quantitative cytomegalovirus standards by use of digital and real-time PCR. J. Clin. Microbiol. 53, 1500–1505. doi: 10.1128/JCM.03375-14

CrossRef Full Text | Google Scholar

Hennechart-Collette, C., Martin-Latil, S., Guillier, L., and Perelle, S. (2015). Determination of which virus to use as a process control when testing for the presence of hepatitis a virus and norovirus in food and water. Int. J. Food Microbiol. 202, 57–65. doi: 10.1016/j.ijfoodmicro.2015.02.029

CrossRef Full Text | Google Scholar

Henrich, T. J., Gallien, S., Li, J. Z., Pereyra, F., and Kuritzkes, D. R. (2012). Low-level detection and quantitation of cellular HIV-1 DNA and 2-LTR circles using droplet digital PCR. J. Virol. Methods 186, 68–72. doi: 10.1016/j.jviromet.2012.08.019

CrossRef Full Text | Google Scholar

ISO/TS 15216-1 (2013). Microbiology of Food and Animal Feed – Horizontal Method for Determination of Hepatitis A Virus and Norovirus in Food using Real-Time RT-PCR – Part 1: Method for Quantification International Organization for Standardiza-tion. Geneva: International Organization for Standardization.

ISO/TS 15216-2 (2013). Microbiology of Food and Animal Feed – Horizontal Method for Determination of Hepatitis A Virus and Norovirus in Food using Real-Time RT-PCR – Part 2: Method for Qualitative Detection. International Organization for Standardiza-tion. Geneva: International Organization for Standardization.

Martin-Latil, S., Hennechart-Collette, C., Guillier, L., and Perelle, S. (2012). Duplex RT-qPCR for the detection of hepatitis E virus in water, using a process control. Int. J. Food Microbiol. 157, 167–173. doi: 10.1016/j.ijfoodmicro.2012.05.001

CrossRef Full Text | Google Scholar

Martin-Latil, S., Hennechart-Collette, C., Guillier, L., and Perelle, S. (2014). Method for HEV detection in raw pig liver products and its implementation for naturally contaminated food. Int. J. Food Microbiol. 176, 1–8. doi: 10.1016/j.ijfoodmicro.2014.01.016

CrossRef Full Text | Google Scholar

Masuda, J., Yano, K., Tamada, Y., Takii, Y., Ito, M., Omagari, K., et al. (2005). Acute hepatitis E of a man who consumed wild boar meat prior to the onset of illness in Nagasaki, Japan. Hepatol. Res. 31, 178–183. doi: 10.1016/j.hepres.2005.01.008

CrossRef Full Text | Google Scholar

Morisset, D., Stebih, D., Milavec, M., Gruden, K., and Zel, J. (2013). Quantitative analysis of food and feed samples with droplet digital PCR. PLoS ONE 8:e62583. doi: 10.1371/journal.pone.0062583

CrossRef Full Text | Google Scholar

Nixon, G., Garson, J. A., Grant, P., Nastouli, E., Foy, C. A., and Huggett, J. F. (2014). Comparative study of sensitivity, linearity, and resistance to inhibition of digital and nondigital polymerase chain reaction and loop mediated isothermal amplification assays for quantification of human cytomegalovirus. Anal. Chem. 86, 4387–4394. doi: 10.1021/ac500208w

CrossRef Full Text | Google Scholar

Okano, H., Takahashi, M., Isono, Y., Tanaka, H., Nakano, T., Oya, Y., et al. (2014). Characterization of sporadic acute hepatitis E and comparison of hepatitis E virus genomes in acute hepatitis patients and pig liver sold as food in Mie, Japan. Hepatol. Res. 44, E63–E76. doi: 10.1111/hepr.12216

CrossRef Full Text | Google Scholar

Pavio, N., Merbah, T., and Thebault, A. (2014). Frequent hepatitis E virus contamination in food containing raw pork liver, France. Emerg. Infect. Dis. 20, 1925–1927. doi: 10.3201/eid2011.140891

CrossRef Full Text | Google Scholar

Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., et al. (2012). Evaluation of a droplet digital polymerase chain reaction format for DNA copy number quantification. Anal. Chem. 84, 1003–1011. doi: 10.1021/ac202578x

CrossRef Full Text | Google Scholar

Racki, N., Dreo, T., Gutierrez-Aguirre, I., Blejec, A., and Ravnikar, M. (2014). Reverse transcriptase droplet digital PCR shows high resilience to PCR inhibitors from plant, soil and water samples. Plant Methods 10:42. doi: 10.1186/s13007-014-0042-6

CrossRef Full Text | Google Scholar

Sanders, R., Mason, D. J., Foy, C. A., and Huggett, J. F. (2013). Evaluation of digital PCR for absolute RNA quantification. PLoS ONE 8:e75296. doi: 10.1371/journal.pone.0075296

CrossRef Full Text | Google Scholar

Smith, D. B., Simmonds, P., International Committee on Taxonomy of Viruses Hepeviridae Study Group, Jameel, S. U., Emerson, T. J., Harrison, X. J., et al. (2014). Consensus proposals for classification of the family Hepeviridae. J. Gen. Virol. 95, 2223–2232.

Google Scholar

Tei, S., Kitajima, N., Takahashi, K., and Mishiro, S. (2003). Zoonotic transmission of hepatitis E virus from deer to human beings. Lancet 362, 371–373. doi: 10.1016/S0140-6736(03)14025-1

CrossRef Full Text | Google Scholar

Wenzel, J. J., Preiss, J., Schemmerer, M., Huber, B., Plentz, A., and Jilg, W. (2011). Detection of hepatitis E virus (HEV) from porcine livers in Southeastern Germany and high sequence homology to human HEV isolates. J. Clin. Virol. 52, 50–54.

Google Scholar

Yazaki, Y., Mizuo, H., Takahashi, M., Nishizawa, T., Sasaki, N., Gotanda, Y., et al. (2003). Sporadic acute or fulminant hepatitis E in Hokkaido, Japan, may be food-borne, as suggested by the presence of hepatitis E virus in pig liver as food. J. Gen. Virol. 84, 2351–2357.

Google Scholar

Yugo, D. M., and Meng, X. J. (2013). Hepatitis E virus: foodborne, waterborne and zoonotic transmission. Int. J. Environ. Res. Public Health 10, 4507–4533. doi: 10.3390/ijerph10104507

CrossRef Full Text | Google Scholar

Keywords: HEV, pig liver, quantification, RT-dPCR, RT-qPCR

Citation: Martin-Latil S, Hennechart-Collette C, Delannoy S, Guillier L, Fach P and Perelle S (2016) Quantification of Hepatitis E Virus in Naturally Contaminated Pig Liver Products. Front. Microbiol. 7:1183. doi: 10.3389/fmicb.2016.01183

Received: 14 April 2016; Accepted: 18 July 2016;
Published: 03 August 2016.

Edited by:

Petr Kralik, Veterinary Research Institute, Czech Republic

Reviewed by:

Achim Weber, University of Zurich, Switzerland
Silvia Monteiro, Instituto Superior Técnico (IST), Portugal

Copyright © 2016 Martin-Latil, Hennechart-Collette, Delannoy, Guillier, Fach and Perelle. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Sylvie Perelle, sylvie.perelle@anses.fr

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.