Commentary: Environmental Sound Training in Cochlear Implant Users

  • Communication Sciences and Disorders, ISU Multimodal Language Processing Lab, Idaho State University, Pocatello, ID, USA

A commentary on
Environmental Sound Training in Cochlear Implant Users

by Shafiro, V., Sheft, S., Kuvadia, S., and Gygi, B. (2015). J. Speech Hear. Lang. Res, 58, 509–519. doi: 10.1044/2015_JSLHR-H-14-0312

Introduction

Cochlear implants (CIs) are prosthetic devices developed for listeners with profound bilateral hearing loss. Despite considerable advances in CI hearing technology allowing for improved speech and language recognition, several studies have reported that the identification of common environmental sounds—even years after implantation plus high speech perception scores—prove difficult for most listeners (e.g., Loebach and Pisoni, 2008; Shafiro et al., 2011, 2015). The literature suggests explanations for environmental sound identification difficulty in CI users: The chief difficulty is that CI signals are highly degraded compared to the frequency-rich neural signal in normal-hearing (NH) listeners. CIs typically include 4 to 22 electrodes; this electrode array, while constituting a drastic improvement from early CIs containing 1 to 4 electrodes, still represents less than 1% of hair cells in a healthy cochlea contributing to sound-frequency information (Wilson, 2004). Besides the degraded signal provided by even state-of-the-art CIs, Shafiro et al. (2015) described other factors complicating environmental sound identification, namely, the likelihood of degraded representations of memory for environmental sounds caused by years of hearing loss.

To help address these concerns, I propose a modification of the environmental sound training procedure initially developed by Shafiro et al. (2015). The aim is to utilize multisensory cues, sounds presented in noise to enhance ecological validity, and a same-different discrimination phase prior to closed-set identification. This modified procedure should enhance neural plasticity, and consequently reconstruct auditory representations that have become degraded after years of CI use.

Training Program Overview

Shafiro et al. (2015) reviewed studies utilizing training programs involving presenting post-lingually deafened CI users with environmental sounds (e.g., Inverso and Limb, 2010; Looi and Arnephy, 2010), or alternatively, presenting NH listeners with either 4 or 8-channel simulated CI signals (Loebach and Pisoni, 2008; Shafiro et al., 2012). Results consistently showed evidence for significant improvement in listeners' ability to identify environmental sounds subsequent to closed-set training. Interestingly, evidence for generalization to other categories was reported, including improved scores in speech recognition by Loebach and Pisoni (2008) and Shafiro et al. (2012) (who examined simulated sounds in NH listeners).

In light of this research showing evidence for improved sound identification, Shafiro et al. (2015) developed a program to train post-lingually deafened CI users on a large closed-set of common sounds, and provide of a short 1-week computerized training program. The procedure consisted of two Pre-Test sessions separated by a week, another week of Training, and two Post-Test sessions each separated by 1 week. Each of these four sessions included two speech recognition tests (the CNC word recognition test; Peterson and Lehiste, 1962, and speech-in-noise SPIN-R; Elliott, 1995). Additionally, the Familiar Environmental Sound Test (FEST) was administered (Shafiro, 2008); FEST includes closed-set identification of 60 familiar sounds (160 words total; four tokens each) across five categories.

Sound-training involved training listeners on a subset of sounds obtained from FEST. On each training trial, a sound was presented and the listener was required to make a closed-set identification response. Feedback was critical to training: When a listener responded incorrectly, the program repeated the correct response three times before advancing to the next trial.

Shafiro et al.'s (2015) results indicated improved performance. Trained items showed the largest degree of improvement. Generalization was reported for untrained items, although performance on untrained items was substantially lower. Generalization, however, failed to occur for word or sentence recognition. Significant individual variability in environmental sound recognition skills was reported subsequent to training. Unfortunately, the authors observed that neither CI brand, length of implantation, nor age accounted for the variability. Variability was also observed across stimuli, with five items receiving particularly low identification scores even after training (e.g., “brushing teeth,” “blowing nose,” “zipper,” and “airplane flying”). Such sounds are “inharmonic,” possessing unique envelope cues that prove difficult for CI users to access.

Optimizing Environmental Sound-Training

To remedy these concerns, I propose a modified multimodal training procedure designed to improve sound-cue acquisition in CI users. Importantly, Shafiro et al. (2015) training utilized feedback. Incorrect responses were repeated three times before continuing. The first proposed modification will involve hierarchically structuring feedback: Each time a listener responds incorrectly, the first cue reinforcement will be to present the (without noise) with a video clip of the sound source. Next, the video will be removed and the same sound (or another token of the same sound) will be presented (again, without noise). The third cue will simply be a presentation of the sound at the same level of background noise used in testing. Studies on a wide variety of topics, from stroke patients with aphasia to traumatic brain injury patient with cognitive deficits support the efficacy of hierarchical cueing (Constantinidou et al., 2008; Abel et al., 2015). In an fMRI study examining the influence of hierarchical cueing therapy on brain reorganization in aphasia patients, Abel et al. (2015) reported that therapy gains appeared were associated with a decrease in brain activation. The observed activation decrease in the experimental group suggests that therapy gains facilitated efficient brain reorganization; efficient in the sense that less brain activation was required to perform the task.

Next, I suggest modifying the procedure by including a same-different detection phase (Phase 1) to reinforce and help encode representations (using two tokens on same trials)—this is especially important for difficult sounds such as “zippers.” Distinguishing “same” vs. “different” requires a lower-level cognitive decision; the ability to distinguish “same” vs. “different” is necessary although not sufficient for identification. Phase 2 will include the identification phase used by Shafiro albeit with the modified cueing procedure (Table 1). In controlled studies, these modifications will hypothetically reinforce auditory representations, improve generalization scores, and reduce variability among listeners and stimulus items.

TABLE 1
www.frontiersin.org

Table 1. Comparison of proposed training procedures.

Author Contributions

The author confirms being the sole contributor of this work and approved it for publication.

Conflict of Interest Statement

The author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

Abel, S., Weiller, C., Huber, W., Willmes, K., and Specht, K. (2015). Therapy-induced brain reorganization patterns in aphasia. Brain 138, 1097–1112. doi: 10.1093/brain/awv022

PubMed Abstract | CrossRef Full Text | Google Scholar

Constantinidou, F., Thomas, R. D., and Robinson, L. (2008). Benefits of categorization training in patients with traumatic brain injury during post–acute rehabilitation: additional evidence from a randomized controlled trial. J. Head Trauma Rehabil. 23, 312–328. doi: 10.1097/01.HTR.0000336844.99079.2c

PubMed Abstract | CrossRef Full Text | Google Scholar

Elliott, L. L. (1995). Verbal auditory closure and the Speech Perception in Noise (SPIN) test. J. Speech Hear. Res. 38, 1363–1376. doi: 10.1044/jshr.3806.1363

PubMed Abstract | CrossRef Full Text | Google Scholar

Inverso, Y., and Limb, C. J. (2010). Cochlear implant-mediated perception of nonlinguistic sounds. Ear Hear. 31, 505–514. doi: 10.1097/AUD.0b013e3181d99a52

PubMed Abstract | CrossRef Full Text | Google Scholar

Loebach, J. L., and Pisoni, D. B. (2008). Perceptual learning of spectrally degraded speech and environmental sounds. J. Acoust. Soc. Am. 123, 1126–1139. doi: 10.1121/1.2823453

PubMed Abstract | CrossRef Full Text | Google Scholar

Looi, V., and Arnephy, J. (2010). Environmental sound perception of cochlear implant users. Cochlear Implants Int. 11, 203–227. doi: 10.1002/cii.428

PubMed Abstract | CrossRef Full Text | Google Scholar

Peterson, G., and Lehiste, I. (1962). Revised CNC list for auditory tests. J. Speech Hear. Disord. 27, 62–70. doi: 10.1044/jshd.2701.62

CrossRef Full Text | Google Scholar

Shafiro, V. (2008). Development of a large-item environmental sound test and the effects of short-term training with spectrally-degraded stimuli. Ear Hear. 29, 775–790. doi: 10.1097/AUD.0b013e31817e08ea

PubMed Abstract | CrossRef Full Text | Google Scholar

Shafiro, V., Gygi, B., Cheng, M. Y., Vachhani, J., and Mulvey, M. (2011). Perception of environmental sounds by experienced cochlear implant patients. Ear Hear. 32, 511–523. doi: 10.1097/AUD.0b013e3182064a87

PubMed Abstract | CrossRef Full Text | Google Scholar

Shafiro, V., Sheft, S., Gygi, B., and Ho, K. (2012). The influence of environmental sound training on the perception of spectrally degraded speech and environmental sounds. Trends Amplif. 16, 83–101. doi: 10.1177/1084713812454225

PubMed Abstract | CrossRef Full Text | Google Scholar

Shafiro, V., Sheft, S., Kuvadia, S., and Gygi, B. (2015). Environmental sound training in cochlear implant users. J. Speech Hear. Lang. Res. 58, 509–519. doi: 10.1044/2015_JSLHR-H-14-0312

PubMed Abstract | CrossRef Full Text | Google Scholar

Wilson, B. S. (2004). “Engineering design of cochlear implant systems,” in Auditory Prostheses: Cochlear Implants and Beyond, eds F. G. Zeng, A. N. Popper, and R. R. Fay (New York, NY: Springer-Verlag), 14–52.

Keywords: cochlear implants, multimodal perception, environmental sound training, individual differences, generalization

Citation: Altieri N (2017) Commentary: Environmental Sound Training in Cochlear Implant Users. Front. Neurosci. 11:36. doi: 10.3389/fnins.2017.00036

Received: 01 November 2016; Accepted: 18 January 2017;
Published: 01 February 2017.

Edited by:

Diego Minciacchi, University of Florence, Italy

Reviewed by:

Angelica Perez Fornos, University of Geneva, Switzerland

Copyright © 2017 Altieri. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Nicholas Altieri, altinich@isu.edu

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.