This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Indirect calorimetry (IC) measurements to estimate resting energy expenditure (REE) necessitate a stable measurement period or steady state (SS). There is limited evidence when assessing the time to reach SS in young, healthy adults. The aims of this prospective study are to determine the approximate time to necessary reach SS using open-circuit IC and to establish the appropriate duration of SS needed to estimate REE. One hundred young, healthy participants (54 males and 46 females; age = 20.6 ± 2.1 years; body weight = 73.6 ± 16.3 kg; height 172.5 ± 9.3 cm; BMI = 24.5 ± 3.8 kg/m2) completed IC measurement for approximately 30 min while the volume of oxygen (VO2) and volume of carbon dioxide (VCO2) were collected. SS was defined by variations in the VO2 and VCO2 of ≤10% coefficient of variation (%CV) over a period of five consecutive minutes. The 30-min IC measurement was divided into six 5-min segments, such as S1, S2, S3, S4, S5, and S6. The results show that SS was achieved during S2 (%CV = 6.81 ± 3.2%), and the %CV continued to met the SS criteria for the duration of the IC measurement (S3 = 8.07 ± 4.4%, S4 = 7.93 ± 3.7%, S5 = 7.75 ± 4.1%, and S6 = 8.60 ± 4.6%). The current study found that in a population of young, healthy adults the duration of the IC measurement period could be a minimum of 10 min. The first 5-min segment was discarded, while SS occurred by the second 5-min segment.
Resting energy expenditure (REE) is the 24-h energy expenditure that reflects the total amount of energy needed to maintain basic physiological function and homeostasis (
In order for IC measurements to be valid and minimize variability, a stable measurement period or steady state (SS) should be achieved during the IC measurement (
The total time period for IC measurement should be minimized in order to create a suitable testing environment for both the participant and investigator. In addition, standardizing the IC measurement protocol with the SS criteria will maximize compatibility and repeatability between researchers. Prior studies assessing the SS methodology of IC have been limited to non-healthy or critically ill patients, postmenopausal women, and older adults (>60 years) (
The aims of this prospective study are to determine an approximate time to reach SS using open-circuit IC and establish the appropriate duration of SS needed to estimate REE. To achieve these aims, a 30-min IC measurement with no prior rest was conducted in young, apparently healthy adults. Based on the results of Borges et al., we hypothesized that the IC measurement length will be 10 min, while SS will be achieved during the second 5 min (
The participants were young, apparently healthy males and females who were recruited
Prior to performing IC measurements, the technicians were trained to use the metabolic cart. They read the manufacturer’s instructions prior to performing multiple practice IC measurements on volunteers who were not included in the study. The same member of the research team trained both technicians, but the technicians were trained separately. After training, they were considered independent. Collin J. Popp or Elliot D. Jesch was present during all IC measurements.
The participants visited the metabolic laboratory between 07:00 a.m. and 11:00 a.m. after a 12-h fast and abstaining from any form of physical activity (other than walking) prior to completing a ventilated, open-circuit IC measurement. Participants were asked to remove excess clothing (e.g., jacket and shoes) and had their height (centimeters) and weight (kilograms) measured using a scale with stadiometer (SECA 763 digital scale, Chino, CA, USA). Then, participants were asked to lay supine on a padded table, and a rigid plastic canopy with a comfortable, flexible seal was placed over the head and torso. Expired gases were analyzed using a calibrated TrueOne® 2400 metabolic cart (ParvoMedics TrueOne®, Murray, UT, USA). The gas analyzers, flow rate, and volume were calibrated as per manufacturer’s recommendations. To ensure quality control between participants and technicians, gas analyzers were calibrated to <0.1% standard gas and flow rate and volume were calibrated to ≤3% error. The ambient temperature was kept between 22 and 26°C, and humidity was maintained at roughly 60%. The participants were required to lay awake for approximately 30 min with no prior rest, and VE parameters were expressed as 30-s averages. REE (kilocalories per day) was calculated based on the Weir equation (
Variables are presented as mean ± SD for each segment and technician. Data were collected separately for both technicians then combined for analysis. The %CV was also calculated for each segment. To compare means among segments, Fisher’s ANOVA
A total of 100 participants completed the REE test, 54 males and 46 females. Ethnicity was not part of the data collection protocol, but most participants were observed to be Caucasian. One male and one female were screened but did not complete the IC test. Their demographic characteristics were not used in the final analysis. One female participant from tech 2’s sample completed the IC test but reported thyroid problems. Her demographics and REE data were excluded from the final analysis. Table
Mean ± SD | |
---|---|
Age (years) | 20.6 ± 2.1 |
Height (cm) | 172.5 ± 9.3 |
Weight (kg) | 73.6 ± 16.3 |
BMI (kg/m2) | 24.5 ± 3.8 |
VO2 (ml/min) | 249.0 ± 55.5 |
VO2 (ml/kg/min) | 3.4 ± 0.6 |
VCO2 (ml/min) | 221.3 ± 57.2 |
REE (kcal/min) | 1.2 ± 0.3 |
REE (kcal/day) | 1750.8 ± 395.7 |
REE (kcals/day/kg) | 24.1 ± 4.2 |
Figure
Figure S1 in Supplementary Material shows changes in REE, SD, and %CV for each technician. The technicians achieved SS at different segments. Tech 1 achieved SS during the S1, and tech 2 achieved SS during S2 (Figures S1E,F in Supplementary Material). The effect size analysis shows a medium effect of technician (
The current prospective study aimed to determine the approximate time to reach SS using open-circuit IC and to establish the appropriate duration of SS needed to estimate REE. The results of the study support the hypothesis that a minimum IC measurement of 10 min, discarding the first 5-min, is acceptable for estimating REE. These results are supported by a non-significant change in mean REE after the S1 segment. In addition, the %CV for each 5-min segment after the first segment continued to meet the SS criteria. The linear regression analysis shows a statistically significant relationship only between participant height and SS %CV, whereas all other participant’s characteristics were non-significant. The participants of both technicians achieved SS at different segments. However, the recommendations we propose would ensure most participants for both tech 1 and tech 2 reach SS by the second 5-min segment.
We set to standardize the IC measurement protocol in the context of young, healthy adults. Prior studies were limited to non-healthy individuals, postmenopausal women, and older adults (
Our results confirm these by Borges et al. found the best abbreviated time for an IC measurement is 10 min, with the first 5 min being discarded (
The present study offers an approximate time to achieve SS. However, our study had a few limitations. We found that 5% of study participants did not reach SS within the 30-min testing period, and interestingly, all were males (3 from tech 1’s sample and 2 from tech 2’s sample). We also noticed that, in some cases, participants reached the SS criteria during the S1 or S2 segment, but their %CV subsequently increased above 10% CV as the measurement continued. This can be explained by the fact that participants were verbally notified during the IC measurement on the amount of time remaining. It is possible that this could have trigged anticipatory reaction leading to an increase in heart rate and increased fidgeting. However, these two variables were not measured. Two full-time undergraduate students (tech 1 and tech 2) completed the data collection procedure. The differences between tech 1 and tech 2 are presented in Supplementary Material. The undergraduate students were trained by the same individual, but at separate times. They may have lacked the necessary experience otherwise observed in an experienced graduate student or researcher. In addition, there was no study done to test for inter-tester reliability. Finally, the results also suggest minimal effect of light activity (e.g., walking, dressing) on REE as SS was achieved within the first 10-min, and participants did not spend the night in the metabolic laboratory. Future research should assess the correlation between the 10-min IC measurement period and 24-h TEE. In addition, our recommended IC protocol should be assessed in a population of working age adults and metabolically stable older adults.
In conclusion, we found that in a population of young, healthy adults the duration of the IC measurement period when measuring REE can be as little as 10 min, with the first 5-min being discarded. SS occurred by the second 5-min segment and continued to meet the SS criteria. Standardizing the IC measurement provides repeatability among researchers who want to best estimate REE, and thus extrapolated to 24-h TEE. Also, this information is important for researchers and practitioners working in a variety of settings for acutely and timely examining energy expenditure for better nutrition and physical activity intervention recommendations.
JT and KS were the two technicians who collected the data. CP, WB, and EJ had substantial contributions to the design, analysis, and interpretation. CP was responsible for drafting and revising the study, and all the authors were involved in approval of the final document submitted. CP and EJ are accountable for resolving questions relating to the accuracy and integrity of the work.
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
We want to thank Nadia Najm, MS, at Clemson University for her contribution during the data collection and manuscript writing process.
This project was funded internally by Clemson University.
The Supplementary Material for this article can be found online at
%CV, percent coefficient of variation; BMI, body mass index; IC, indirect calorimetry; REE, resting energy expenditure; SS, steady state; TEE, total energy expenditure; VCO2, volume of carbon dioxide; VO2, volume of oxygen.