Skip to main content

ORIGINAL RESEARCH article

Front. Pharmacol., 06 April 2018
Sec. Ethnopharmacology

Development of an Ultrasonication-Assisted Extraction Based HPLC With a Fluorescence Method for Sensitive Determination of Aflatoxins in Highly Acidic Hibiscus sabdariffa

\r\nXiaofei LiuXiaofei Liu1Guangyao Ying,Guangyao Ying1,2Chaonan SunChaonan Sun1Meihua YangMeihua Yang1Lei ZhangLei Zhang1Shanshan Zhang,Shanshan Zhang1,2Xiaoyan XingXiaoyan Xing1Qian LiQian Li1Weijun Kong*Weijun Kong1*
  • 1Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
  • 2College of Pharmacy, Jinzhou Medical University, Jinzhou, China

The high acidity and complex components of Hibiscus sabdariffa have provided major challenges for sensitive determination of trace aflatoxins. In this study, sample pretreatment of H. sabdariffa was systematically developed for sensitive high performance liquid chromatography-fluorescence detection (HPLC-FLD) after ultrasonication-assisted extraction, immunoaffinity column (IAC) clean-up and on-line post-column photochemical derivatization (PCD). Aflatoxins B1, B2, G1, G2 were extracted from samples by using methanol/water (70:30, v/v) with the addition of NaCl. The solutions were diluted 1:8 with 0.1 M phosphate buffer (pH 8.0) to negate the issues of high acidity and matrix interferences. The established method was validated with satisfactory linearity (R > 0.999), sensitivity (limits of detection (LODs) and limits of quantitation (LOQs) of 0.15–0.65 and 0.53–2.18 μg/kg, respectively), precision (RSD <11%), stability (RSD of 0.2–3.6%), and accuracy (recovery rates of 86.0–102.3%), which all met the stipulated analytical requirements. Analysis of 28 H. sabdariffa samples indicated that one sample incubated with Aspergillus flavus was positive with aflatoxin B1 (AFB1) at 3.11 μg/kg. The strategy developed in this study also has the potential to reliably extract and sensitively detect more mycotoxins in other complex acidic matrices, such as traditional Chinese medicines, foodstuffs, etc.

Introduction

Aflatoxins (AFs) are highly toxic secondary metabolites mainly produced by the toxigenic fungi Aspergillus flavus and Aspergillus parasiticus that display severe mutagenic, carcinogenic and teratogenic effects (Peraica, 1999; The Joint FAO/WHO Expert Committee on Food Additives, 2012). Aflatoxins are regarded as Group I carcinogens to humans by the World Health Organization [WHO] and International Agency for Research on Cancer [IARC] (1993), and they tend to contaminate a large number of foods and herbal medicines, posing serious threats to the safety of both animals and humans. Because of the detrimental effects of AFs, many countries and organizations have set maximum levels (MLs) for aflatoxin B1 (AFB1) as well as AFs (sum of aflatoxin B1, B2, G1, G2) in a wide range of foodstuffs, herbal medicines and other matrices. The tolerance levels of AFB1 set by the European Commission are 5–20 μg/kg in various matrices (European Commission, 2010), while MLs of AFB1 and AFs posed by Chinese pharmacopeia (Chinese Pharmacopoeia Commission, 2015) are 5 and 10 μg/kg, respectively.

Because of their acute virulence and wide occurrence combined with ultra-low levels in various matrices, current analytical methods for analysis of AFs mainly include thin layer chromatography (TLC) (Stroka et al., 2009), enzyme-linked immunosorbent assay (ELISA) (Li et al., 2009), and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) (Xie et al., 2015; Pesek et al., 2017). However, these methods have several drawbacks including inaccurate quantitation, false-positive results and expensive equipment (Iqbal et al., 2014). Considering the fluorescence quenching properties of AFB1 and AFG1 in water, the aforementioned drawbacks can be overcome by utilizing high-performance liquid chromatography with fluorescence detection after post-column photochemical derivatization (HPLC-PCD-FLD). This alternative method provided rapid and sensitive detection of AFs in many different types of matrices (Wen et al., 2013; Kong et al., 2014; Kara et al., 2015; Golge et al., 2016; Campos et al., 2017).

Matrix interference is a major challenge for accurate analysis of AFs in traditional Chinese medicines (TCMs) (Bothast and Hesseltine, 1975; Gosetti et al., 2010). Therefore, an appropriate pretreatment step is necessary to purify the sample and enrich for AFs. Liquid-liquid extraction (LLE) (Afzali et al., 2012; Campone et al., 2011; Andrade et al., 2013), matrix solid-phase dispersion (MSPD) (Alessandra et al., 2016), solid-phase extraction (SPE) (Blesa et al., 2003; Alcaide-Molina et al., 2009; Luca et al., 2015; Zhou et al., 2017), quick easy cheap effective rugged and safe (QuEChERS) pretreatment (Desmarchelier et al., 2014) and immunoaffinity column (IAC) methods (Ma et al., 2013; Rhemrev et al., 2015; Wilcox et al., 2015; Xie et al., 2015) have been carried out for multi-matrix cleanup prior to analysis of AFs to eliminate matrix interference. Due to the high selectivity and efficiency, the introduction of IAC can overcome the shortcomings of non-specificity, solvent consumption, and poor efficiency of other cleanup techniques, which has been recommended by the Association of Official Analytical Chemists (AOAC) (Rhemrev et al., 2015). The IAC cleanup technique is primarily based on antibodies that are highly specific to their targets (such as AFs) for sensitive recognition and detection. However, the physical and chemical properties of TCMs, such as their complex makeup varying pH value influence both the stability of antibodies and their ability to recognize their targets, causing low IAC cleanup efficiency and recovery.

The dried calyx and bract of Hibiscus sabdariffa L. (family Malvaceae) (Alarcon-Aguilar et al., 2007) are the common ingredients of herbal drinks, hot and cool beverages, and flavoring agents in the food industry. They are also frequently used drugs in clinical trials, where they exhibit anti-bacterial, antifungal, anti-parasitic, anti-pyretic and anti-inflammatory properties (Sindi et al., 2014). H. sabdariffa also has high nutritional values due to its large quantities of protein, carbohydrates, fiber, vitamin C and minerals (Mahadevan et al., 2009; Da-Costa-Rocha et al., 2014; Sindi et al., 2014). Drinking of H. sabdariffa tea daily has a positive impact on blood pressure in type II diabetic patients (Mozaffari-Khosravi et al., 2009) and reduces hypercholesterolaemia (Aziz et al., 2013). However, the safety and quality of TCMs are threatened by mold and various fungi that can thrive under the high temperatures and humidity condition during the growth, processing, storage and transportation progresses, which can lead to aflatoxin contamination (Wang et al., 2012; Akhund et al., 2017). And the occurrence of aflatoxins contamination in many matrices including herbal medicines of leaves and flowers has been reported (Han et al., 2010, 2012; Tan et al., 2012; Zheng et al., 2014). It is also investigated that H. sabdariffa samples from Uyo and Akpan markets were contaminated by AFB1 (Adebayo-tayo and Samuel, 2009). Therefore, it is of great urgency to develop reliable methods for sensitive detection of aflatoxins in H. sabdariffa. But, the high acidity and complex matrix interferences have been obstacles for H. sabdariffa sample preparation and clean-up for detection of trace aflatoxins.

In this study, we describe ideal pretreatment conditions that account for the high acidity and complex compon ents of H. sabdariffa samples. We systematically optimized the sample pretreatment procedure including extraction technique, the dilution ratio of sample solutions and the buffer dilution solution. This is the first report on detection of aflatoxins by HPLC-PCD-FLD in acidic sample like H. sabdariffa. This strategy provides essential guidance for monitoring toxic contaminates in H. sabdariffa and can be applied to other highly acidic TCMs and foodstuffs, and feeds, etc.

Materials and Methods

Protection and Safety Statement

Due to the extremely strong toxicity of aflatoxins, necessary cautions and essential protections are needed throughout the whole experiments according to strict guidelines. Anti-poison respirators, isolation gowns and goggles were used. After being contaminated with aflatoxins, the containers and consumables were dipped in 10% sodium hypochlorite in a specified holder for at least 24 h. The lab garbage was disposed in an appropriate way.

Reagents and Chemicals

The IAC-ToxinFast®-Aflatoxins Test IACs were supplied by Huaan Magnech Bio-Tech Co., Ltd. (Beijing, China). The TGL 16M centrifuge was bought from Hunan Kaida Scientific Instrument Co., Ltd. (Changsha, China) and PB-10 pH meter from Sartorius Intec (Hamburg, Germany). HPLC grade methanol and acetonitrile were purchased from Fisher Scientific (Fair Lawn, NJ, United States). Other reagents and chemicals of analytical grade were obtained from Beijing Chemical Works (Beijing, China). Deionized water was purified by the Milli-Q Plus ultra-pure water system (Millipore, Billerica, MA, United States).

Phosphate buffer saline (PBS) was prepared by dissolving 0.2 g KCl, 0.2 g KH2PO4, 8.0 g NaCl, and 1.2 g Na2HPO4 in 1000 mL of pure water at pH 7.4. 0.1 M NaH2PO4 solution was set as Solution A, which was obtained by dissolving 1.56 g NaH2PO4⋅2H2O in 100 mL of pure water, while Solution B was obtained by dispersing 35.8 g Na2HPO4⋅12H2O in 1000 mL of pure water. 0.1 M Phosphate buffer (PB), encompassing 60 mL of Solution A and 940 mL of Solution B, was homogeneously mixed and afterward the pH value was adjusted to 8.0 with 0.1 M HCl. 0.5%, 1%, and 2% PBST (PBS with addition of Tween-20) solutions were got by adding 5, 10 and 20 mL of Tween-20 into 1000 mL PBS (pH 7.4), respectively.

Instrumentation and HPLC Conditions

All analyses were performed on a Shimadzu LC-20AT HPLC system (Shimadzu, Kyoto, Japan) consisting of two LC-20 AT pumps, an SIL-20A autosampler, a CTO-20A column oven, a CMB-20A controller, the post-column PCD reactor and an RF-20AXL fluorescence detector. The PCD reactor with a mercury lamp (λ = 254 nm) and a knitted reactor coil of 0.74 mL (15 m × 0.25 mm) was bought from AURA Industries (New York, NY, United States). The eluate was monitored by using a fluorescence detector with an excitation wavelength of 360 nm and an emission wavelength of 450 nm. The chromatographic separation of tested aflatoxins was conducted on a CAPCELL PAK C18 column (4.6 mm ID × 150 mm, 5 μm) at constant 30°C. HPLC separation of four AFs was carried out by using methanol and acetonitrile (40: 18, v/v) with the water phase (pure water) as the mobile phase at isocratic elution. Injection volume was 20 μL and the flow rate was set at 1.2 μL/min. The total run time was 30 min.

Working Standard Solution

Aflatoxins standard including 2 μg AFB1, 2 μg AFG1, 0.5 μg AFB2, 0.5 μg AFG2 in 1 mL of acetonitrile were bought from Pribolab (Singapore). Working standard solution was prepared by diluting the standards with methanol to get 200 ng/mL of AFB1, AFG1 and 25 ng/mL of AFB2, AFG2. All the standard solutions were stored at -20°C in the dark before analysis.

Sample Collection

Twenty-six batches of H. sabdariffa samples including 6 batches of ground powder (S1–S6), 11 batches of crude materials (S7–S17) and 9 kinds of scented teas (S18–S26) were randomly collected from Guangxi, Sichuan, Anhui, Guangdong and Yunnan provinces, Beijing city of China and Thailand. 500 g sample was used for the preparation of sample solution. A positive control (S28) was obtained by inoculating the sample from Beijing city with A. flavus spores while another fraction of this sample (S27) was kept at the same incubation conditions without A. flavus. All crude samples and scented teas were identified by Prof. Meihua Yang (Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences, Peking Union Medical College). All the samples were thoroughly triturated to obtain consistent particle size and homogenized samples. The sub-sample and scented teas were powdered and sieved through a 24-mesh sieve. All samples were classified and labeled clearly in lock bags while stored in a cool dry place before use.

Sample Preparation

Fungal Spore Suspension Preparation

The A. flavus spore suspensions were prepared according to a previously reported method (Christensen et al., 2012) with some modifications. After 1 week of incubation, 10.0 mL of sterile water was spiked onto the Czapek Dox Agar (CDA) medium (Aobox Biotechnology Co., Ltd., Beijing, China) with A. flavus. After standing for 1 min, the yellow-green spore was scraped down with a sterile inoculating loop. After mixed with sterile glass beads in a 15-mL aseptic centrifuge tube, the spore suspension was diluted with sterile water to 1 × 105 spores/mL as determined by using a haemocytometer slide (0.1 mm depth, 1/400 mm2) and XDS-1B optical microscope (Chongqing COIC Instrument Co., Ltd., Chongqing, China).

Preparation of Artificial Moldy Samples

Approximately 20.0 g of the H. sabdariffa sample purchased from Beijing city was sterilized under an ultraviolet lamp for 1 h. Then, the sterilized sample was inoculated with A. flavus spores by trans-inoculation to produce a contaminated H. sabdariffa control. Inoculation was performed as follows: 50 mL of A. flavus spore suspension (1 × 105 spores/mL) was added onto the surface of the sample, which was covered and incubated for 30 min at constant humidity and temperature (90% relative humidity, 28°C). Afterwards, spore suspension was removed and the sample was incubated under the same conditions for 20 days. A sample that was not inoculated with the A. flavus was also incubated for 20 days (90% relative humidity, 28°C). The moldy H. sabdariffa sample was powdered and stored at -20°C in the freezer for further utilization.

Extraction Procedure

The described method in Chinese Pharmacopeia (Chinese Pharmacopoeia Commission, 2015) after some modifications was used. H. sabdariffa (5.00 g ± 0.01 g) was mixed in a 50-mL centrifuge tube with 1.00 g NaCl and 25 mL of methanol/water (70:30, v/v) solution. The mixture was homogenized by swirling for 2 min, and then was extracted by ultrasonication in an ultrasonic bath at 500 W for 20 min. The slurry was separated at 10,000 rpm for 5 min at 20°C. Immediately after 5 mL of the upper phase was transferred into a new centrifuge tube, 40 mL of 0.1 M PB (pH 8.0) was added to dilute the sample 1:8. The diluent was filtered through 0.45-μm glass fiber filter paper for the next cleanup step.

Immunoaffinity Column Cleanup

The resulting 40 mL of filtrate was passed through an immunoaffinity column (IAC-ToxinFast®-Aflatoxins Test) at a flow rate of approximately 3 mL/min at room temperature for at least 30 min. When the filtrate nearly passed through the column, 20 mL of ultra-pure water was added to wash the column at a flow rate of 3 mL/min. Finally, all the residual liquid was excluded with clean air. Next, 1.5 mL of methanol was added onto the IAC for elution of the aflatoxins. The final volume of the eluate was brought to 2 mL with methanol. After being mixed uniformly, the final solution was filtered through a 0.22-μm glass fiber filter paper.

Analytical Measurement

Sensitive quantitation of four AFs in H. sabdariffa samples in the form of ground powder, crude herbs and scented teas was carried out by measuring the peak area responses in the HPLC-FLD chromatograms at eachg aflatoxin retention time and comparing them with the linear equation of a calibration graph. The peak area (y-axis) of each aflatoxin was plotted against the concentration (ng/mL, x-axis) and expressed as a linear equation y = ax+ b. By determining the values of slope (a) and y-intercept (b), the equations were established and the content of each aflatoxin in the tested sample was calculated.

Method Validation

For accurate determination of four target aflatoxins in H. sabdariffa samples with high acidity, the established HPLC-PCD-FLD method was validated according to EU Regulation No. 401/2006 (The Commission of the European Communities, 2006) in terms of linearity, limit of detection (LOD) and limit of quantitation (LOQ), accuracy, precision, stability, selectivity and robustness.

Statistical Analysis

Each experiment was performed in triplicate and all the data were represented as mean ± standard error (SE) and analyzed by ANOVA using SPSS software (version 19.0). Means were separated by Tukey’s multi-range tests when ANOVA results were significant (P < 0.05).

Results and Discussion

This work aimed to develop a simple, rapid and sensitive method for reliable determination of four aflatoxins in the acidic sample, H. sabdariffa by HPLC-FLD after ultrasonication-assisted extraction, IAC cleanup, and online post-column PCD. Some key conditions and parameters for sample preparation and IAC cleanup were optimized to amend the acidity by decreasing pH and eliminate impurities in the samples.

Sample Pretreatment Optimization

Results of preliminary experiments using the recommended method (Chinese Pharmacopoeia Commission, 2015) for detection of AFs in H. sabdariffa showed that the four AFs (AFB1, AFB2, AFG1, AFG2) were not adequately separated and recovered. Unfavorable detection was due to complex matrix components and the high acidity of this TCM. To overcome these issues, we modified and improved sample pretreatment and cleanup for sensitive HPLC-FLD analysis. First of all, necessary work was reasonably performed on different dilution ratios of pure water. The sample extract was diluted with pure water at dilution ratios of 1:4 and 1:8 (v/v). These dilutions were inadequate to recoveries of AFs at the required levels of 70–110%. Therefore, other highly effective dilution reagents were taken into consideration.

Selection of the Buffer Dilution Solution

The optimal pH value for IACs is in a range of 6.0–8.0. The mean pH value of the above-mentioned diluent in water at 1:8 ratio was around 2.4, which will weaken the stability of antibodies and their target affinity. Few immune reactants would be out of function under this condition. Diluting the sample just with water to provide buffer capacity and minimize the matrix was not sufficient to overcome the strongly acidic matrix of H. sabdariffa (Da-Costa-Rocha et al., 2014).

To resolve the problem, PBS (Ip and Che, 2006) was introduced to adjust the pH of the test solution before application onto the IACs. Unfortunately, it was found that the recoveries of AFG1 and AFG2 still did not meet the official requirements. To address this issue, Tween-20 (Zhang et al., 2017) was added into the buffer, and three levels (0.5, 1 and 2%, v/v) of Tween-20 were compared to screen the most effective buffer dilution solution. Increasing the volume of Tween-20, the recoveries of AFs went up mildly (Figure 1). However, even with 2% Tween-20 in PBS (pH 7.4) the recovery of AFG2 did not meet the requirement.

FIGURE 1
www.frontiersin.org

FIGURE 1. Recoveries of spiked H. sabdariffa samples with 5.0 μg/kg of AFB1 and AFG1, 1.25 μg/kg of AFB2 and AFG2 in different dilution solutions of (A) 0.1 M PB (pH 8.0); (B) PBS (pH7.4); (C) PBS (pH7.4)-0.5% Tween-20; (D) PBS (pH7.4)-1% Tween-20; (E) PBS (pH7.4) -2% Tween-20.

For extracts of H. sabdariffa with such high acidity (around pH3.0), 0.1 M PB (pH 8.0), which has a greater buffering capacity, could be used to successfully adjust the pH to the appropriate range (pH > 6.0) for IAC. When 0.1 M PB (pH 8.0) was used for dilution, the recoveries of four aflatoxins in H. sabdariffa increased sharply to acceptable levels (Figure 1).

By diluting samples with 0.1 M PB (pH 8.0), matrix interferences were minimized and AFs recoveries were within the standard range. Therefore, to ensure that the concentrations of AFs in the final eluates could successfully reach the LODs and to decrease useless hands-on time, a dilution ratio of 1:8 (v/v) was finally chosen.

Optimization of Sample Extraction Technique

Using a suitable sample extraction technique plays an important role in trace detection for effectively extracting aflatoxins in H. sabdariffa without increasing impurities. A homogeneous extraction technique has been recommended (Chinese Pharmacopoeia Commission, 2015). Here, two simple and commonly used techniques including homogeneous extraction for 3 min at 11,000 rpm with a homogenizer and ultrasonication-assisted extraction in an ultrasonic bath at 500 W for 20 min were both tested to compare their efficacy in extracting AFs from spiked H. sabdariffa samples with 5.0 μg/kg of AFB1 and AFG1, and 1.25 μg/kg of AFB2 and AFG2. Recoveries of the four AFs in spiked H. sabdariffa samples were all over 80%, but the values obtained from ultrasonication-assisted extraction were all higher than that from homogeneous extraction (P < 0.05) (Figure 2). We found that after homogeneous treatment, a large quantity of the sample solution was adhered to the surface of the stirring arm. In addition, with this method, samples were processed sequentially and the machinery had to be washed carefully between testing, resulting in wasted analytes and time. Therefore, ultrasonication-assisted extraction using 70% methanol was chosen for sample preparation. With the application of modifications, the recoveries of four aflatoxins met the trace analysis requirements.

FIGURE 2
www.frontiersin.org

FIGURE 2. Recoveries of spiked H. sabdariffa samples with 5.0 μg/kg of AFB1 and AFG1, 1.25 μg/kg of AFB2 and AFG2 using different extraction techniques.

Method Validation

The method was validated for linearity, LOD and LOQ, accuracy, precision, stability, selectivity and robustness described as follows.

Linearity and LOD, LOQ

The standard curve for each aflatoxin was performed by a serial concentration of the standard solutions. Six concentrations of AFB1 and AFG1 (0.625, 1.25, 2.5, 5.0, 10.0, 20.0 ng/mL) and five concentrations of AFB2 and AFG2 (0.3125, 0.625, 1.25, 2.50, 5.0 ng/mL) were generally diluted and performed in triplicate for the linearity of each aflatoxin, respectively. Four independent linear relationships of instrument response (area of target peak, y) and target concentration (x) satisfactorily showed in appropriate detection ranges (Table 1) with correlation coefficients (R) > 0.999.

TABLE 1
www.frontiersin.org

TABLE 1. Linearity, LOD and LOQ for tested aflatoxins.

Limits of detection (LODs) and limits of quantitation (LOQs) were carried out by serial dilution of standard solutions, which referred to the concentrations of the standards when the ratios of signal of chromatographic peak to noise (signal-to-noise ratio, S/N) were 3 and 10, respectively. The S/N ratios were calculated by Analyst Software (version 1.6.2). The LODs and LOQs were between 0.15–0.65 μg/kg and 0.53–2.18 μg/kg, respectively (Table 1), which were below the MLs defined in EU and Chinese pharmacopeia (2015 edition). So, the method was sensitive enough for HPLC-FLD analysis.

Accuracy, Precision and Stability

The accuracy of the established HPLC-FLD method was assessed in recovery at three levels of aflatoxins in normal (aflatoxins-free) samples. The recoveries at three levels (low, medium and high concentrations in Table 2) were 86.0–98.9%, 90.7–102.3% and 95.0–101.8%, respectively, which met the official requirements.

TABLE 2
www.frontiersin.org

TABLE 2. Precision, recoveries and stability for Hibiscus sabdariffa spiked with four aflatoxins.

The normal sample was spiked with a 5 μg/kg standard solution for evaluating method precision. Precision data (RSD%) was estimated by repeated analysis (n = 6) of the fortified sample spiked with AFs at the MLs concentration. Intra- and inter-day precisions analyses were also carried out (Table 2). RSD values of 6.3–10.2% (n = 6) and 4.4–7.3% (n = 6, 6 days) were below the references in the European Commission Regulations, showing good precision of the developed method.

Additionally, the stability of a series of AFs standard solutions (stored at 4°C for 1 week in the dark) was measured every day (7 days in total). Repeated results (RSDs 0.2–3.6%) showed that the standard solutions of four aflatoxins (AFB1, AFB2, AFG1, and AFG2) were stable under these circumstances for 1-week storage (Table 2).

Selectivity and Robustness

The selectivity of the developed HPLC-FLD method for sample clean-up and enrichment was evaluated by IAC. The immuno-adsorption between AFs and antibodies indicated that the IAC method with post-column PCD was selective. After optimization of the chromatographic conditions mentioned above, the chromatograms exhibited the expected results for the mixed standard solution. AFs in the fortified sample with 5.0 μg/kg of AFB1 and AFG1, 1.25 μg/kg of AFB2 and AFG2 were effectively separated in 27 min (Figure 3). There were no interference peaks at the retention time when each target aflatoxin was observed.

FIGURE 3
www.frontiersin.org

FIGURE 3. Typical HPLC-FLD chromatograms of (A) AFs standard solution, (B) normal sample, and (C) artificial moldy H. sabdariffa sample positive with AFB1.

Robustness, as an index for variations, remained unaffected by small but notable variations during the testing procedure. In this assay, the slight variations of water composition (±0.01%) in mobile phase and in column temperature above or below 0.2°C did not affect the results. Therefore, our newly technique was robust.

Real Samples Analysis

To confirm the suitability and versatility of our optimized pretreatment conditions including ultrasonication-assisted extraction and IAC cleanup, the validated HPLC-FLD analytical procedure after online PCD was applied for simultaneous determination of four AFs in 28 H. sabdariffa samples including 6 batches of ground powders, 11 batches of crude materials and 9 kinds of scented teas purchased from different markets, herbal shops and bazaars in China and Thailand, and two man-made moldy samples. The HPLC-FLD chromatograms showed that the four AFs were well separated with satisfactory responses under the present chromatographic conditions (Figure 3). No interference peaks were detected at the retention time of each aflatoxin in the normal (AFs-free) and moldy samples. The occurrence and contents of four AFs in different H. sabdariffa samples for this survey were summarized in Table 3. One artificial moldy control sample after being inoculated with A. flavus spores for 20 days was tested to be positive for AFB1 at 3.11 μg/kg, which did not exceed the MLs set by China and other international organizations. Because of its important medicinal values and world-wide consumption, it is important to monitor the occurrence and levels of aflatoxins especially AFB1 in H. sabdariffa products to ensure quality and safety.

TABLE 3
www.frontiersin.org

TABLE 3. Occurrence and contents of four AFs in different H. sabdariffa samples from different origins.

Conclusion

In this study, by systematically optimizing the sample pretreatment conditions including the dilution ratio, type of buffer and the sample extraction technique, a simple, sensitive and rapid HPLC-PCD-FLD method after IAC cleanup has been developed for simultaneous determination of four AFs in different types of H. sabdariffa samples. The established HPLC-PCD-FLD method posted sensitive and accurate detection of aflatoxins to overcome the major analytical challenges of high acidity and low concentration of targets in Hibiscus sabdariffa. Compared to other pretreatment procedures, the modified extraction and suitable IAC clean-up method can achieve highly effective recognition of trace AFs in highly acidic H. sabdariffa samples, leading to satisfactory LODs for the targets.

After systematic optimization, the developed method should be applicable for the sensitive detection of more mycotoxins in other types of TCM matrices of high acidity to ensure their quality and safety. In addition, the elucidation of fungal behavior, together with the influence of mycotoxins contamination on the quality of H. sabdariffa is a relevant focus in the future.

Author Contributions

XL wrote the paper. GY, WK, and XL conceived and designed the experiments. SZ, LZ, and QL performed the sample preparation and chemical pretreatments. GY and CS contributed to preparing artificial moldy samples. XL, GY, and XX gave rise to analyzing the data. MY and WK reviewed the paper and funded the project. WK was responsible for submission.

Funding

This work was supported by the National Natural Science Foundation of China (81673593 and 81473346), CAMS Innovation Fund for Medical Sciences (2016-I2M-3-010 and 2017-I2M-1-013), and Beijing Natural Science Foundation (7152101).

Conflict of Interest Statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

Adebayo-tayo, B. C., and Samuel, A. U. (2009). Microbial quality and proximate composition of dried Hibiscus sabdariffa calyxes in Uyo, Eastern Nigeria. Malays. J. Microbiol. 5, 13–18. doi: 10.21161/mjm.12608

CrossRef Full Text | Google Scholar

Afzali, D., Ghanbarianb, M., Mostafavi, A., Shamspur, T., and Ghaseminezhad, S. (2012). A novel method for high preconcentration of ultra trace amounts of B1, B2, G1 and G2 aflatoxins in edible oils by dispersive liquid-liquid microextraction after immunoaffinity column clean-up. J. Chromatogr. A 47, 35–41. doi: 10.1016/j.chroma.2012.05.051

PubMed Abstract | CrossRef Full Text | Google Scholar

Akhund, S., Akram, A., Hanif, N. Q., Qureshi, R., Naz, F., and Nayyar, B. G. (2017). Pre-harvest aflatoxins and Aspergillus flavus contamination in variable germplasms of red chillies from Kunri, Pakistan. Mycotoxin Res. 33, 147–155. doi: 10.1007/s12550-017-0274-1

PubMed Abstract | CrossRef Full Text | Google Scholar

Alarcon-Aguilar, F. J., Zamilpa, A., Perez-Garcia, M. D., Almanza-Perez, J. Z., Romero-Nuñez, E., Campos-Sepilveda, E. A., et al. (2007). Effect of Hibiscus sabdariffa on obesity in MSG mice. J. Ethnopharmacol. 114, 66–71. doi: 10.1016/j.jep.2007.07.020

PubMed Abstract | CrossRef Full Text | Google Scholar

Alcaide-Molina, M., Ruiz-Jiménez, J., Mata-Granados, J. M., and de Castro, L. D. (2009). High through-put aflatoxin determination in plant material by automated solid-phase extraction on-line coupled to laser-induced fluorescence screening and determination by liquid chromatography–triple quadrupole mass spectrometry. J. Chromatogr. A 1216, 1115–1125. doi: 10.1016/j.chroma.2008.12.049

PubMed Abstract | CrossRef Full Text | Google Scholar

Alessandra, G., Valeria, D. P., Fulvia, C., Virginia, P. F., Pierpaolo, T., Roberta, C., et al. (2016). Residue analysis of thyreostats in baby foods via Matrix Solid Phase Dispersion and liquid chromatography-dual-polarity electrospray-tandem mass spectrometry. Food Addit. Contam. Part A 33, 1793–1802.

PubMed Abstract | Google Scholar

Andrade, P. D., da Silva, J. L. G., and Caldas, E. D. (2013). Simultaneous analysis of aflatoxins B1, B2, G1, G2, M1 and ochratoxin A in breast milk by high-performance liquid chromatography/fluorescence after liquid–liquid extraction with low temperature purification (LLE-LTP). J. Chromatogr. A 1304, 61–68. doi: 10.1080/19440049.2016.1241899

PubMed Abstract | CrossRef Full Text | Google Scholar

Aziz, Z., Wong, S. Y., and Chong, N. J. (2013). Effects of Hibiscus sabdariffa L. onserumlipids: a systematic review and meta-analysis. J. Ethnopharmacol. 150, 442–450. doi: 10.1016/j.chroma.2013.06.049

PubMed Abstract | CrossRef Full Text | Google Scholar

Blesa, J., Soriano, J. M., Moltó, J. C., Marín, R., and Mañes, J. (2003). Determination of aflatoxins in peanuts by matrix solid-phase dispersion and liquid chromatography. J. Chromatogr. A 1011, 49–54. doi: 10.1016/j.jep.2013.09.042

PubMed Abstract | CrossRef Full Text | Google Scholar

Bothast, R. J., and Hesseltine, C. W. (1975). Bright greenish-yellow fluorescence and aflatoxin in agricultural commodities. Appl. Environ. Microbiol. 30, 337–338.

PubMed Abstract | Google Scholar

Campone, L., Piccinelli, A. L., Celano, R., and Rastrelli, L. (2011). Application of dispersive liquid–liquid microextraction for the determination of aflatoxins B1. B2, G1 and G2 in cereal products. J. Chromatogr. A 1218, 7648–7654. doi: 10.1016/j.chroma.2011.05.028

PubMed Abstract | CrossRef Full Text | Google Scholar

Campos, W. E. O., Rosas, L. B., Neto, A. P., Mello, R. A., and Vasconcelos, A. A. (2017). Extended validation of a senstive and robust method for simultaneous quantification of aflatoxins B1, B2, G1 and G2 in Brazil nuts by HPLC-FLD. J. Food Compos. Anal. 60, 90–96. doi: 10.1016/j.jfca.2017.03.014

CrossRef Full Text | Google Scholar

Chinese Pharmacopoeia Commission (2015). Chinese Pharmacopoeia of the People’s Republic of China, Vol. 4. Bejing: Chinese Medicine Science and Technology Press.

Google Scholar

Christensen, S., Borrego, E., Shim, W. B., Isakeit, T., and Kolomiets, M. (2012). Quantification of fungal colonization, sporogenesis, and production of mycotoxins using kernel bioassays. J. Vis. Exp. 62:3727. doi: 10.3791/3727

PubMed Abstract | CrossRef Full Text | Google Scholar

Da-Costa-Rocha, I., Bonnlaender, B., Sievers, H., Pischel, I., and Heinrich, M. (2014). Hibiscus sabdariffa L. -A phytochemical and pharmacological review. Food Chem. 165, 424–443. doi: 10.1016/j.foodchem.2014.05.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Desmarchelier, A., Tessiot, S., Bessaire, T., Racault, L., Fiorese, E., et al. (2014). Combining the quick, easy, cheap, effective, rugged and safe approachand clean-up by immunoaffinity column for the analysis of 15 mycotoxins by isotope dilution liquid chromatography tandem mass spectrometry. J. Chromatogr. A 1337, 75–84. doi: 10.1016/j.chroma.2014.02.025

PubMed Abstract | CrossRef Full Text | Google Scholar

European Commission (2010). Commission Regulation (EC) No 165/2010 of 26 February 2010 amending regulation (EC) no. 1881/2006 setting maximum levels for certain contaminants in foodstuffs as regards aflatoxins. Off. J. Eur. Union 38, 8–10.

Google Scholar

Golge, O., Hepsag, F., and Kabak, B. (2016). Determination of aflatoxins in walnut sujuk and Turkish delight by HPLC-FLD method. Food Control 59, 731–736. doi: 10.1016/j.foodcont.2015.06.035

CrossRef Full Text | Google Scholar

Gosetti, F., Mazzucco, E., Zampieri, D., and Gennaro, M. C. (2010). Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry. J. Chromatogr. A 1217, 3929–3937. doi: 10.1016/j.chroma.2009.11.060

PubMed Abstract | CrossRef Full Text | Google Scholar

Han, Z., Ren, Y. P., Zhu, J. F., Cai, Z. X., Chen, Y., Luan, L. J., et al. (2012). Multianalysis of 35 mycotoxins in traditional Chinese medicines by ultra-high-performance liquid chromatography-tandem mass spectrometry coupled with accelerated solvent extraction. J. Agric. Food Chem. 60, 8233–8247. doi: 10.1021/jf301928r

PubMed Abstract | CrossRef Full Text | Google Scholar

Han, Z., Zheng, Y. L., Luan, L. J., Cai, Z. X., Ren, Y. P., and Wu, Y. J. (2010). An ultra-high-performance liquid chromatography-tandem mass spectrometry method for simultaneous determination of aflatoxins B1, B2, G1, G2, M1 and M2 in traditional Chinese medicines. Anal. Chim. Acta 664, 165–171. doi: 10.1016/j.aca.2010.02.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Ip, S. P., and Che, C. T. (2006). Determination of aflatoxins in Chinese medicinal herbs by high-performance liquid chromatography using immunoaffinity column cleanup Improvement of recovery. J. Chromatogr. A 1135, 241–244. doi: 10.1016/j.chroma.2006.10.025

PubMed Abstract | CrossRef Full Text | Google Scholar

Iqbal, J., Asghar, M. A., Ahmed, A., Khan, M. A., and Jamil, K. (2014). Aflatoxins contamination in Pakistani brown rice: a comparison of TLC, HPLC, LC–MS/MS and ELISA techniques. Toxicol. Mech. Methods 24, 544–551. doi: 10.3109/15376516.2014.948247

PubMed Abstract | CrossRef Full Text | Google Scholar

Kara, G. N. K., Ozbey, F., and Kabak, B. (2015). Co-occurrence of aflatoxins and ochratoxin A in cereal flours commercialised in Turkey. Food Control 54, 275–281. doi: 10.1016/j.foodcont.2015.02.014

CrossRef Full Text | Google Scholar

Kong, W. J., Wei, R. W., Logrieco, A. F., Wei, J. H., Wen, J., Xiao, X. H., et al. (2014). Occurrence of toxigenic fungi and determination of mycotoxins by HPLC-FLD in functional foods and spices in China markets. Food Chem. 146, 320–326. doi: 10.1016/j.foodchem.2013.09.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Li, P. W., Zhang, Q., Zhang, W., Zhang, J. Y., Chen, X. M., Jiang, J. J., et al. (2009). Development of a class-specific monoclonal antibody-based ELISA for aflatoxins in peanut. Food Chem. 115, 313–317. doi: 10.1016/j.foodchem.2008.11.052

CrossRef Full Text | Google Scholar

Luca, C., Anna, L. P., Rita, C. M. R., Alberto, V., and Clara, I. L. R. (2015). A fully automated method for simultaneous determination of aflatoxins and ochratoxin A in dried fruits by pressurized liquid extraction and online solid-phase extraction cleanup coupled to ultra-high-pressure liquid chromatography-tandem mass spectrometry. Anal. Bioanal. Chem. 407, 2899–2911. doi: 10.1007/s00216-015-8518-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Ma, F., Chen, R., Li, P. W., Zhang, Q., Zhang, W., and Hu, X. F. (2013). Preparation of an immunoaffinity column with amino-silica gel microparticles and its application in sample cleanup for aflatoxin detection in agri-products. Molecules 18, 2222–2235. doi: 10.3390/molecules18022222

PubMed Abstract | CrossRef Full Text | Google Scholar

Mahadevan, N., Shivali, and Kamboj, P. (2009). Hibiscus sabdariffa Linn. An overview. Nat. Prod. Radiance 8, 77–83.

Google Scholar

Mozaffari-Khosravi, H., Jalali-Khanabadi, B. A., Afkhami-Ardekani, M., Fatehi, F., and Noori-Shadkam, M. (2009). The effects of sour tea (Hibiscus sabdariffa) on hypertension in patients with type II diabetes. J. Hum. Hypertens. 23, 48–54. doi: 10.1038/jhh.2008.100

PubMed Abstract | CrossRef Full Text | Google Scholar

Peraica, M., Radić, B., Lucić, A., and Pavlović, M. (1999). Toxic effects of mycotoxins in humans. Bull. World Health Oran. 77, 754–766.

Google Scholar

Pesek, J. J., Matyska, M. T., Hoffmann, J. F., Madruga, N. A., Crizel, R. L., Elias, M. C., et al. (2017). Liquid chromatography with mass spectrometry analysis of mycotoxins in food samples using silica hydride based stationary phases. J. Sep. Sci. 40, 1953–1959. doi: 10.1002/jssc.201601267

PubMed Abstract | CrossRef Full Text | Google Scholar

Rhemrev, R., Pazdanska, M., Marley, E., Biselli, S., and Staiger, S. (2015). Automated aflatoxin analysis using inline reusable immunoaffinity column cleanup and LC-fluorescence detection. J. AOAC Int. 98, 1585–1590. doi: 10.5740/jaoacint.15-124

PubMed Abstract | CrossRef Full Text | Google Scholar

Sindi, H. A., Marshall, L. J., and Morgan, M. R. (2014). Comparative chemical and biochemical analysis of extracts of Hibiscus sabdariffa. Food Chem. 164, 23–29. doi: 10.1016/j.foodchem.2014.04.097

PubMed Abstract | CrossRef Full Text | Google Scholar

Stroka, J., Otterdijk, R. V., and Anklam, E. (2009). Immunoaffinity column clean-up prior to thin-layer chromatography for the determination of aflatoxins in various food matrices. J. Chromatogr. A 4, 251–256.

PubMed Abstract | Google Scholar

Tan, J., Zheng, R. S., Wang, W. L., and Xu, H. (2012). Simultaneous determination of aflatoxins and zearalenone in Chinese crude drugs by high performance liquid chromatography-tandem mass spectrometry. Shizhen Guoyi Guoyao 23, 2469–2472.

Google Scholar

The Commission of the European Communities (2006). Commission Regulation (EC) No 401/2006 of 23 February 2006 Criteria for sample preparation and for methods of analysis used for the official control of the levels of mycotoxins in foodstuffs. Off. J. Eur. Union L. 70:31.

The Joint FAO/WHO Expert Committee on Food Additives (2012). “Safety evaluation of certain food additives and contaminants,” in Proceedings of the Sixtyfirst Meeting of the Joint FAO/WHO Expert Committee on Food Additives, Geneva.

Google Scholar

Wang, H., Lu, Z. Y., Qu, H. J., Liu, P. P., Miao, C. D., Zhu, T. H., et al. (2012). Antimicrobial aflatoxins from the marine-derived fungus Aspergillus flavus 092008. Arch. Pharm. Res. 35, 1387–1392. doi: 10.1007/s12272-012-0808-1

PubMed Abstract | CrossRef Full Text | Google Scholar

Wen, J., Kong, W. J., Wang, J., and Yang, M. H. (2013). Simultaneous determination of four aflatoxins and ochratoxin A in ginger and related products by HPLC with fluorescence detection after immunoaffinity column clean-up and postcolumn photochemical derivatization. J. Sep. Sci. 36, 3709–3716. doi: 10.1002/jssc.201300885

PubMed Abstract | CrossRef Full Text | Google Scholar

Wilcox, J., Donnelly, C., Leeman, D., and Marley, E. (2015). The use of immunoaffinity columns connected in tandem for selective and cost-effective mycotoxin clean-up prior to multi-mycotoxin liquid chromatographic–tandem mass spectrometric analysis in food matrices. J. Chromatogr. A 1400, 91–97. doi: 10.1016/j.chroma.2015.04.053

PubMed Abstract | CrossRef Full Text | Google Scholar

World Health Organization [WHO] and International Agency for Research on Cancer [IARC] (1993). Some naturally occurring substances: food items and constituents, heterocylic aromatic amines and mycotoxins. IARC Monogr. Eval. Carcinog. Risks Hum 56:599.

Google Scholar

Xie, J., Peng, T., He, J. L., Shao, Y., Fan, C. L., Chen, Y., et al. (2015). Preparation and characterization of an immunoaffinity column for the selective extraction of aflatoxin B1 in 13 kinds of foodstuffs. J. Chromatogr. B 99, 50–56. doi: 10.1016/j.jchromb.2015.06.022

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, L., Dou, X. W., Kong, W. J., Liu, C. M., Han, X., and Yang, M. H. (2017). Assessment of critical points and development of a practical strategy to extend the applicable scope of immunoaffinity column cleanup for aflatoxin detection in medicinal herbs. J. Chromatogr. A 1483, 56–63. doi: 10.1016/j.chroma.2016.12.079

PubMed Abstract | CrossRef Full Text | Google Scholar

Zheng, R. S., Xu, H., Wang, W. L., Zhan, R. T., and Chen, W. W. (2014). Simultaneous determination of aflatoxin B1, B2, G1, G2, ochratoxin A, and sterigmatocystin in traditional Chinese medicines by LC–MS–MS. Anal. Bioanal. Chem. 406, 3031–3039. doi: 10.1007/s00216-014-7750-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhou, N. Z., Liu, P., Su, X. C., Liao, Y. H., Lei, N. S., Liang, Y. H., et al. (2017). Low-cost humic acid-bonded silica as an effective solid-phase extraction sorbent for convenient determination of aflatoxins in edible oils. Anal. Chim. Acta 970, 38–46. doi: 10.1016/j.aca.2017.02.029

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: Hibiscus sabdariffa, high acidity, aflatoxins, ultrasonication-assisted extraction, IAC improvement, HPLC-FLD

Citation: Liu X, Ying G, Sun C, Yang M, Zhang L, Zhang S, Xing X, Li Q and Kong W (2018) Development of an Ultrasonication-Assisted Extraction Based HPLC With a Fluorescence Method for Sensitive Determination of Aflatoxins in Highly Acidic Hibiscus sabdariffa. Front. Pharmacol. 9:284. doi: 10.3389/fphar.2018.00284

Received: 09 August 2017; Accepted: 13 March 2018;
Published: 06 April 2018.

Edited by:

Lyndy Joy McGaw, University of Pretoria, South Africa

Reviewed by:

Jelena Cvejic, University of Novi Sad, Serbia
Ayhan Filazi, Ankara University, Turkey

Copyright © 2018 Liu, Ying, Sun, Yang, Zhang, Zhang, Xing, Li and Kong. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Weijun Kong, kongwj302@126.com

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.