Skip to main content

MINI REVIEW article

Front. Physiol., 30 November 2017
Sec. Exercise Physiology
This article is part of the Research Topic Wearable Sensor Technology for Monitoring Training Load and Health in the Athletic Population View all 29 articles

Monitoring Energy Expenditure Using a Multi-Sensor Device—Applications and Limitations of the SenseWear Armband in Athletic Populations

  • 1Department of Nutrition and Health Sciences, University of Nebraska-Lincoln, Lincoln, NE, United States
  • 2Division of Physical Education, University of Education Upper Austria, Linz, Austria

In order to monitor their energy requirements, athletes may desire to assess energy expenditure (EE) during training and competition. Recent technological advances and increased customer interest have created a market for wearable devices that measure physiological variables and bodily movement over prolonged time periods and convert this information into EE data. This mini-review provides an overview of the applicability of the SenseWear armband (SWA), which combines accelerometry with measurements of heat production and skin conductivity, to measure total daily energy expenditure (TDEE) and its components such as exercise energy expenditure (ExEE) in athletic populations. While the SWA has been shown to provide valid estimates of EE in the general population, validation studies in athletic populations indicate a tendency toward underestimation of ExEE particularly during high-intensity exercise (>10 METs) with an increasing underestimation as exercise intensity increases. Although limited information is available on the accuracy of the SWA during resistance exercise, high-intensity interval exercise, or mixed exercise forms, there seems to be a similar trend of underestimating high levels of ExEE. The SWA, however, is capable of detecting movement patterns and metabolic measurements even at high exercise intensities, suggesting that underestimation may result from limitations in the proprietary algorithms. In addition, the SWA has been used in the assessment of sleep quantity and quality as well as non-exercise activity thermogenesis. Overall, the SWA provides viable information and remains to be used in various clinical and athletic settings, despite the termination of its commercial sale.

Introduction: Tracking Energy Expenditure in Athletes

One of the unique characteristics of athletes is that energy requirements of training and competition increase their total daily energy expenditure (TDEE) beyond those of the general population (Westerterp, 2013). Energy requirements can vary considerably depending on exercise type, intensity, and duration, but sustained levels of energy expenditure (EE) can be in the range of 5,000–8,000 kcal/day (Westerterp et al., 1986; Westerterp, 2001). This high energy turnover has implications not only for weight gain and weight loss practices, which are prominent in sports with weight classes, anti-gravitational sports, or aesthetic sports; it also necessitates a sufficient dietary energy intake, as sustained energy deficiency can result in long-term detriments including impaired bone health and infertility (Loucks et al., 2011). In addition, recent data suggest that athletic performance may also be impaired in energy-deprived athletes (Vanheest et al., 2013).

Because of the high energy demands and the consequences of energy deficiency, tracking EE is paramount for many athletes and their support staff. Considering that athletes expend up to 75% of their TDEE during exercise (Westerterp, 2013), quantifying energy needs during training and competition requires particular attention. The current gold-standard method for the assessment of TDEE in free-living situations is the doubly labeled water (DLW) method, which has been used in numerous athletic settings (Westerterp et al., 1986; Sjödin et al., 1994; Trappe et al., 1997; Hill and Davies, 2001, 2002; Ebine et al., 2002; Ekelund et al., 2002; Koehler et al., 2010). However, the time resolution is limited and the method does not differentiate between various components contributing to TDEE, such as exercise energy expenditure (ExEE) (Westerterp et al., 1986). Improved resolution is provided by indirect calorimetry (IC), the reference method for EE quantification in controlled laboratory settings (Haugen et al., 2007). However, despite recent methodological advances, the method remains mostly limited to research and exercise testing. Further, the requirement of a face mask hinders natural training behaviors such as fluid or food intake. Therefore, other approaches that do not interfere with training and competition practices are needed to reliably quantify EE, and particularly ExEE, in athletes.

Available methods include accelerometry, pedometry, heart-rate monitors, and self-report methods (Ndahimana and Kim, 2017). With the exception of self-report methods, which only provide subjective information and show low accuracy and reliability (Ndahimana and Kim, 2017), all of these approaches have been incorporated in activity monitors. These devices are less cost-prohibitive than DLW or IC, can be used during a wide range of activities and numerous settings, and allow for data collection over prolonged time intervals in large cohorts (Düking et al., 2016). Several such wearable devices, including the ActiGraph, Actical, RT3, ActivePAL, or GeneActiv, have been developed for research purposes, and various companies have introduced commercial physical activity trackers (e.g., Fitbit, Garmin, Jawbone, Nike). However, as these devices typically rely only on accelerometry, they provide mixed accuracy with regard to its ability to predict EE or time spent in different activities (Welk et al., 2007) and the ability to detect when devices are worn may be limited (Jaeschke et al., 2017).

Technology of the SenseWear Armband: Features, Functions, and Modifications

The SenseWear armband (SWA) developed by BodyMedia Inc. (Pittsburgh, PA, USA) combines accelerometry with additional biological variables, such as heat flux, skin temperature, near-body ambient temperature, and galvanic skin response. The device only collects data when it is in direct contact with the skin and its pattern-recognition algorithm has been shown to provide more accurate results for estimating EE and time spent in various activities when compared to the ActiGraph (Welk et al., 2007). Given these benefits, the SWA became a promising tool to objectively monitor EE in various exercise and non-exercise settings (Fruin and Rankin, 2004). Most basic principles and functions have remained the same since the initial introduction of the first prototypes in the late 1990s, but there have been several upgrades, the most notable modification being the addition of a third dimension accelerometer axis (Riou et al., 2015) along with increased data transfer and storage capacity. Per manufacturer instructions, the SWA is worn on the upper left arm, and can be used to record data continuously for up to 3–4 weeks (Koehler et al., 2013). Data can be downloaded, viewed, and exported for subsequent data processing using manufacturer software (InnerView, BodyMedia, Pittsburgh, PA). A proprietary algorithm converts raw data into estimates of EE, which are expressed both in kcal/min and metabolic equivalents (METs). In efforts to improve the validity of the SWA, this algorithm has been modified several times (Jakicic et al., 2004; Van Hoye et al., 2015). Although the technology was purchased by a competitor in 2013 and has since been discontinued (Welk et al., 2017), the SWA continues to be used extensively in research and clinical settings (Figure 1). Considering the continued popularity and the current lack of alternatives on the market, it was our goal to provide a critical review of the applicability of the SWA to measure EE specifically in athletes. As such, we provide a general overview of the strength and limitations of the SWA in the general population (section Validity of the SenseWear Armband in the General Population: Energy Expenditure, Physical Activity, and Exercise), followed by a review of the validity of the SWA in athletes and during various types of high-intensity exercise (section Validity of the SenseWear Armband during High-Intensity Exercise). We further discuss possible reasons for limitations (section Limitations of the SenseWear Armband: Algorithm vs. Methodology) and non-traditional applications of the SWA in athletic settings (section Application of the SenseWear Armband in Athletic Populations). To identify appropriate literature, a quasi-systematic PUBMED search (https://www.ncbi.nlm.nih.gov/pubmed/) was conducted in June 2017 independently by both authors, using “SenseWear” in combination with “exercise,” “activity,” or “athletes” as search terms. In addition, we included literature cited. Final inclusion was decided on by a joint decision from both authors based on each paper's relevance to the review's target group.

FIGURE 1
www.frontiersin.org

Figure 1. Distribution of publications including the search term “SenseWear” for the period from 2004 (first publication) to 2016 (last complete year); data source: https://www.ncbi.nlm.nih.gov/pubmed/ (Aug 14, 2017).

Validity of the SenseWear Armband in the General Population: Energy Expenditure, Physical Activity, and Exercise

In the general population, the SWA has been validated extensively and has been shown to provide accurate estimates of TDEE as well as EE at rest and during activities of light to moderate intensities when compared to DLW or IC (Cole et al., 2004; Fruin and Rankin, 2004; Jakicic et al., 2004; King et al., 2004; Mignault et al., 2005; Papazoglou et al., 2006; Malavolti et al., 2007; Patel et al., 2007; St-Onge et al., 2007; Johannsen et al., 2010; Casiraghi et al., 2013; Brazeau et al., 2016). When specific time periods of varying activity intensities were examined, however, the SWA generally overestimated EE at lower intensities, while EE was underestimated at higher intensities (Cole et al., 2004; Fruin and Rankin, 2004; Jakicic et al., 2004; Patel et al., 2007; Dwyer et al., 2009; Berntsen et al., 2010; Benito et al., 2012; Gastin et al., 2017). Accordingly, TDEE was overestimated in participants with low levels of TDEE and underestimated in participants with high TDEE (St-Onge et al., 2007; Johannsen et al., 2010).

It should further be considered that the accuracy of the SWA is impacted by external factors such as treadmill incline, exercise mode (e.g., running vs. bicycling), or the use of the upper vs. lower body exercise (Fruin and Rankin, 2004; Jakicic et al., 2004; Berntsen et al., 2010; Vernillo et al., 2015; Brazeau et al., 2016; Gastin et al., 2017). Specifically, underestimation of EE during uphill walking has been reported in several studies, with increasing measurement errors at steeper inclines (Fruin and Rankin, 2004; Jakicic et al., 2004; Vernillo et al., 2015). Downhill walking, on the other hand, was associated with an overestimation of EE, and—although less pronounced—measurement errors increased as declines became steeper (Vernillo et al., 2015). During stationary cycling, total EE did not differ between the SWA and IC, but individual time point data were poorly correlated: At the beginning of the cycling trial, EE was underestimated, but EE estimates by the SWA increased gradually over time even though IC values remained stable (Fruin and Rankin, 2004; Brazeau et al., 2016). Further, Gastin et al. (2017) reported an underestimation of EE during resistance type circuit exercise, most likely due to inaccuracies at higher intensities. In addition to problems related to activity type and intensity, body weight has been shown to affect measurement accuracy. Even though no particular bias toward over- or underestimation of EE was observed, measurement error increased with increasing BMI (Dwyer et al., 2009; Malavolti et al., 2012). Considering that athletes typically are on the extreme ends of the body composition spectrum (Meyer et al., 2013), it is unclear to which degree body weight or composition contribute to measurement errors in athletes.

Differences in body weight or composition may also contribute to the considerable variability of measurement accuracy at the individual level (Fruin and Rankin, 2004; Brazeau et al., 2016). Nevertheless, a recent study reported accurate measurements of TDEE with a mean difference of 2.8 kcal/day and narrow 95% confidence intervals (−34.8 to 40.3 kcal/day) and a correlation coefficient of r = 0.88 when comparing SWA values to DLW in 191 generally healthy adults with diverse body weight and physical activity levels (Drenowatz et al., 2017). Overall, the SWA provides valid estimates of TDEE and ExEE with a measurement error of typically <10% in a recreationally active population.

Validity of the SenseWear Armband during High-Intensity Exercise

To our knowledge, only one study has assessed the validity of SWA-measured TDEE specifically in athletes. Koehler et al. (2011) reported an average difference of 65 kcal/day (<2% of TDEE) between TDEE measured by SWA and DLW in 14 endurance trained athletes and a moderate to strong correlation (r = 0.73) However, higher levels of TDEE tended to be underestimated by the SWA, and the level of underestimation was related to the participant's exercise capacity, whereby EE was underestimated to a greater degree in better trained athletes (Koehler et al., 2011).

Validity during High-Intensity Aerobic Exercise

Several studies have tested the validity of the SWA during high-intensity, continuous aerobic exercise. In two independent studies in trained male athletes, the SWA underestimated ExEE during treadmill running at speeds of ~10.1 km/h (6.3 miles/h) and greater (Koehler et al., 2011, 2013). These findings were replicated by Drenowatz and Eisenmann (2011), who demonstrated that ExEE was consistently underestimated in endurance-trained athletes running at 65, 75, and 85% of their aerobic capacity, corresponding to a similar speed range (9.9–14.6 km/h; 6.2–9.1 miles/h). In another study, the SWA underestimated ExEE even at speeds from 6.0 to 7.2 km/h (3.7–4.5 miles/h) (van Hoye et al., 2014). Similar findings were also reported during stationary bicycling, whereby the SWA underestimated ExEE at workloads between 140 and 380 W (Koehler et al., 2011). In all cases, the level of underestimation increased with increasing exercise intensity (Drenowatz and Eisenmann, 2011; Koehler et al., 2011, 2013; van Hoye et al., 2014). However, visual inspection of the combined data from all five studies (Figure 2) suggests that differences between SWA and IC are rather modest at low-to-moderate exercise intensities. At exercise intensities above 35 mL/kg/min (10 METs) SWA-measured ExEE, however, tends to plateau whereas IC-measured ExEE increases continuously, resulting in a stark increase in the level of underestimation. It is noteworthy that all studies employed an incremental exercise test to assess the validity of the SWA at multiple exercise intensities. To our knowledge, only one study separately used a 30 min exercise bout at a self-selected intensity, resulting in a similar level of underestimation of 27% (Drenowatz and Eisenmann, 2011).

FIGURE 2
www.frontiersin.org

Figure 2. Previously published data reporting the discrepancy between energy expenditure measured with the SenseWear armband (black symbols) in comparison to the reference method (indirect calorimetry; open symbols) and the difference between SenseWear and indirect calorimetry (gray symbols). The dotted line depicts an exercise intensity of 35 mL/kg/min (10 METs). Data published by Drenowatz and Eisenmann (2011) stem from 20 male and female runners (VO2peak: 57 mL/kg/min); Data published by Koehler et al. (2011) stem from 14 triathletes (VO2peak: 58 mL/kg/min) who were assessed while running and biking; Data published by Koehler et al. (2013) stem from 19 endurance and strength trained men (VO2peak: 55 mL/kg/min) who were assessed while running; Data from van Hoye et al. (2014) stem from 23 male kinesiology students (VO2peak: 69 mL/kg/min) and 20 female kinesiology students (VO2peak: 53 mL/kg/min) who were assessed while walking and running; Data published by Van Hoye et al. (2015) stem from 39 male and female kinesiology students (VO2peak: 58 mL/kg/min) who were assessed while walking and running.

Validity during Resistance Exercise

Only few studies have examined the accuracy of the SWA during resistance-type exercise. Benito et al. (2012) reported an underestimation of ExEE during circuit-type resistance training at 30, 50, and 70% of the 15RMmax in a mixed sample of 29 recreationally active participants. Compared to IC, SWA-estimated ExEE was 32% lower in men, corresponding to a difference of 2.3 METs, and 21% lower in women (1.1 METs). Furthermore, the degree of underestimation increased with increasing exercise intensity, although this effect was only significant in men (Benito et al., 2012). On the other hand, the SWA slightly overestimated exercise EE by an average 35 kcal per session during self-selected resistance exercise in a mixed sample of 52 participants of varying age and fitness level (Bai et al., 2016). The measurement error at the individual level was reported at 15%. However, the average exercise intensity was rather low during these sessions (3.2 METs) and may not resemble a typical resistance exercise session in athletic populations. Using a more traditional resistance training protocol of 9 exercises covering all major muscle groups with 3 sets of 10 repetitions at 70% of the 1-reptition maximum, the SWA provided accurate estimates of ExEE with an error of less than 5% and a strong correlation for ExEE (r = 0.77) and TDEE (r = 0.97) (Reeve et al., 2014). Measurement errors also remained constant across the ExEE spectrum with an almost perfect reliability of the SWA (test-retest r = 0.96). It should, however, be considered that ExEE was integrated over the course of the exercise bout; no information was provided on the measurement accuracy for specific exercise types (Reeve et al., 2014).

Validity during Mixed Exercise Forms

Similar to studies addressing resistance-type exercise, there has been only limited research examining the accuracy of the SWA during mixed exercise forms, particularly in athletic populations. Zanetti et al. (2014) assessed the accuracy of the SWA during a 42-min sport-specific intermittent exercise trial in 14 male rugby players. While there was no clear trend toward over- or underestimation of ExEE with a mean bias of −0.2 kcal/min (−1.9%), results revealed only a moderate correlation between the SWA and IC (r = 0.55). During a 30-min basketball-specific skill session, the SWA, however, was shown to underestimate ExEE by 1.1 kcal/min (15%) (Taylor, 2012). EE during recovery period following intermittent exercise training, on the other hand, was overestimated by 17% by the SWA when compared to IC (Zanetti et al., 2014).

Limitations of the SenseWear Armband: Algorithm vs. Methodology

Despite the tendency to underestimate ExEE during high-intensity exercise, available data suggest that the SWA can reliably detect activity patterns, rest periods, and varying levels of exercise intensity within individuals. For example, significant intra-individual correlations between IC and SWA was reported in 90% of endurance athletes who ran at exercise intensities between 65 and 85% VO2max (Drenowatz and Eisenmann, 2011). In another study involving incremental treadmill running at speeds between 10.8 and 17.3 km/h, raw data including acceleration counts, and particularly counts in the longitudinal plane, increased continuously as workload increased (Koehler et al., 2013), demonstrating that the technology is suited to detect movement patterns even at higher exercise intensities. Consequently, limitations to the proprietary algorithm are a candidate source for the underestimation of ExEE during high-intensity exercise. Several studies have tested whether algorithm adjustments could improve the validity of the SWA during exercise. In one of the first published validation studies, Jakicic et al. (2004) reported that the accuracy of the SWA improved after algorithm revisions. After the initial algorithm underestimated ExEE during walking, stepping, and cycling by 7–29% and overestimated ExEE during arm ergometry by 29%, the researchers provided a subset of their data to develop exercise-specific proprietary equations, which reduced errors in ExEE measured by the SWA to a non-significant level. However, ExEE values, which peaked during stair stepping at 5.3–9.2 kcal/min, did not exceed the 10 MET-threshold. More recently, Van Hoye et al. (2015) compared two different algorithms during low- and moderate-intensity treadmill running in well-trained students, reasoning that a newer algorithm would provide more accurate estimates of EE as the manufacturer updates proprietary algorithms on a regular basis. When compared to the initially used algorithm (version 2.2.), data processed using a newer algorithm (version 5.2) reduced the measurement error from 18–24 to 5–17%, although ExEE remained underestimated.

Application of the SenseWear Armband in Athletic Populations

Despite the previously mentioned limitations, several groups have used the SWA to track EE in athletes. In adolescent sprinters undergoing high-intensity exercise training, Aerenhouts et al. (2011) measured TDEE, ExEE, and activity patterns using the SWA. When compared to self-report, the SWA registered less time spent in high-intensity activity, although this difference did not result in differences in TDEE, which was within 6% of the TDEE derived from activity diaries. The authors also highlighted the need for additional information when athletes fail to wear the SWA for 24 h. The SWA was also used to record ExEE during the competitive season in volleyball players (Woodruff and Meloche, 2013). SWA-recorded ExEE was found to be higher during games when compared to practice and warm-up sessions. Combining SWA data with diet logs and body composition assessment, the authors further concluded that the majority of the athletes were in an energy-balanced state. Using the SWA to quantify non-exercise activity thermogenesis (NEAT) among endurance athletes undergoing periods of high and low training volume, Drenowatz et al. (2013) demonstrated that the high training volume did not result in a compensatory reduction in NEAT; instead, athletes reduced their sedentary activities to allow for more training time. In professional Australian Football players, the SWA was used to document the contribution of NEAT to TDEE, which was greater on training days (85%) when compared to match days (69%) (Walker et al., 2016).

Because the SWA can be worn continuously for several days, it has also been used for the assessment of sleep quantity and quality. In male elite rugby union players, SWA-derived sleep duration was shown to be lower during game nights when compared to non-game nights, although sleep efficiency was not different (Eagles and Lovell, 2016). In another trial comparing high-intensity interval training to strength training, SWA-derived sleep efficiency was lower in the high-intensity interval condition (Kölling et al., 2016). These applications demonstrate that the SWA is well-suited to capture other biological factors, such as characteristics of sleep and NEAT, that may have important implications for athletic performance.

Conclusion and Summary

Considering that the SWA has been designed for a broad market, it is not surprising that the device tends to underestimate ExEE for periods of high-intensity exercise. Although most data has been established for aerobic exercise, the SWA seems to equally underestimate ExEE during other exercise forms. When energy expenditure is integrated over longer time periods, including rest and recovery, the measurement error becomes less pronounced and estimations of TDEE tend to be more accurate, even in athletic populations. Adjustments to the proprietary algorithm that is used to derive EE may further help to improve the validity of the SWA. Unfortunately the sale of the SWA has been terminated. Recently, a new disposable device with similar functionality has been introduced but is not available for commercial application at this time (Welk et al., 2017). Another viable option is the combination of GPS data with accelerometry and heart rate to assess EE in outdoor sports (Costa et al., 2015), although the accuracy of such devices remains to be explored. Given the current lack of alternatives, the SWA continues to be used in research and practice, emphasizing the need for the continued development of wearable devices that reliably measure EE and related variables in athletic settings.

Author Contributions

All authors listed have made a substantial, direct and intellectual contribution to the work, and approved it for publication.

Conflict of Interest Statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

Aerenhouts, D., Zinzen, E., and Clarys, P. (2011). Energy expenditure and habitual physical activities in adolescent sprint athletes. J. Sports Sci. Med. 10, 362–368.

PubMed Abstract | Google Scholar

Bai, Y., Welk, G. J., Nam, Y. H., Lee, J. A., Lee, J. M., Kim, Y., et al. (2016). Comparison of consumer and research monitors under semistructured settings. Med. Sci. Sports Exerc. 48, 151–158. doi: 10.1249/MSS.0000000000000727

PubMed Abstract | CrossRef Full Text

Benito, P. J., Neiva, C., González-Quijano, P. S., Cupeiro, R., Morencos, E., and Peinado, A. B. (2012). Validation of the sensewear armband in circuit resistance training with different loads. Eur. J. Appl. Physiol. 112, 3155–3159. doi: 10.1007/s00421-011-2269-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Berntsen, S., Hageberg, R., Aandstad, A., Mowinckel, P., Anderssen, S. A., Carlsen, K. H., et al. (2010). Validity of physical activity monitors in adults participating in free-living activities. Br. J. Sports Med. 44, 657–664. doi: 10.1136/bjsm.2008.048868

PubMed Abstract | CrossRef Full Text | Google Scholar

Brazeau, A. S., Beaudoin, N., Bélisle, V., Messier, V., Karelis, A. D., and Rabasa-Lhoret, R. (2016). Validation and reliability of two activity monitors for energy expenditure assessment. J. Sci. Med. Sport 19, 46–50. doi: 10.1016/j.jsams.2014.11.001

PubMed Abstract | CrossRef Full Text | Google Scholar

Casiraghi, F., Lertwattanarak, R., Luzi, L., Chavez, A. O., Davalli, A. M., Naegelin, T., et al. (2013). Energy expenditure evaluation in humans and non-human primates by sensewear armband. Validation of energy expenditure evaluation by sensewear armband by direct comparison with indirect calorimetry. PLoS ONE 8:e73651. doi: 10.1371/journal.pone.0073651

PubMed Abstract | CrossRef Full Text | Google Scholar

Cole, P. J., LeMura, L. M., Klinger, T. A., Strohecker, K., and McConnell, T. R. (2004). Measuring energy expenditure in cardiac patients using the body media armband versus indirect calorimetry. A validation study. J. Sports Med. Phys. Fitness 44, 262–271.

PubMed Abstract | Google Scholar

Costa, S., Ogilvie, D., Dalton, A., Westgate, K., Brage, S., and Panter, J. (2015). Quantifying the physical activity energy expenditure of commuters using a combination of global positioning system and combined heart rate and movement sensors. Prev. Med. 81, 339–344. doi: 10.1016/j.ypmed.2015.09.022

PubMed Abstract | CrossRef Full Text | Google Scholar

Drenowatz, C., and Eisenmann, J. C. (2011). Validation of the sensewear armband at high intensity exercise. Eur. J. Appl. Physiol. 111, 883–887. doi: 10.1007/s00421-010-1695-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Drenowatz, C., Eisenmann, J. C., Pivarnik, J. M., Pfeiffer, K. A., and Carlson, J. J. (2013). Differences in energy expenditure between high- and low-volume training. Eur. J. Sport Sci. 13, 422–430. doi: 10.1080/17461391.2011.635707

PubMed Abstract | CrossRef Full Text | Google Scholar

Drenowatz, C., Hill, J. O., Peters, J. C., Soriano-Maldonado, A., and Blair, S. N. (2017). The association of change in physical activity and body weight in the regulation of total energy expenditure. Eur. J. Clin. Nutr. 71, 377–382. doi: 10.1038/ejcn.2016.228

PubMed Abstract | CrossRef Full Text | Google Scholar

Düking, P., Hotho, A., Holmberg, H. C., Fuss, F. K., and Sperlich, B. (2016). Comparison of non-invasive individual monitoring of the training and health of athletes with commercially available wearable technologies. Front. Physiol. 7:71. doi: 10.3389/fphys.2016.00071

PubMed Abstract | CrossRef Full Text | Google Scholar

Dwyer, T. J., Alison, J. A., McKeough, Z. J., Elkins, M. R., and Bye, P. T. (2009). Evaluation of the sensewear activity monitor during exercise in cystic fibrosis and in health. Respir. Med. 103, 1511–1517. doi: 10.1016/j.rmed.2009.04.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Eagles, A. N., and Lovell, D. I. (2016). Changes in sleep quantity and efficiency in professional rugby union players during home-based training and match play. J. Sports Med. Phys. Fitness 56, 565–571.

PubMed Abstract | Google Scholar

Ebine, N., Rafamantanantsoa, H. H., Nayuki, Y., Yamanaka, K., Tashima, K., Ono, T., et al. (2002). Measurement of total energy expenditure by the doubly labelled water method in professional soccer players. J. Sports Sci. 20, 391–397. doi: 10.1080/026404102317366645

PubMed Abstract | CrossRef Full Text | Google Scholar

Ekelund, U., Yngve, A., Westerterp, K., and Sjöström, M. (2002). Energy expenditure assessed by heart rate and doubly labeled water in young athletes. Med. Sci. Sports Exerc. 34, 1360–1366. doi: 10.1097/00005768-200208000-00019

PubMed Abstract | CrossRef Full Text

Fruin, M. L., and Rankin, J. W. (2004). Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med. Sci. Sports Exerc. 36, 1063–1069. doi: 10.1249/01.MSS.0000128144.91337.38

PubMed Abstract | CrossRef Full Text | Google Scholar

Gastin, P. B., Cayzer, C., Dwyer, D., and Robertson, S. (2017). Validity of the ActiGraph GT3X+ and bodymedia sensewear armband to estimate energy expenditure during physical activity and sport. J. Sci. Med. Sport. doi: 10.1016/j.jsams.2017.07.022. [Epub ahead of print].

PubMed Abstract | CrossRef Full Text

Haugen, H. A., Chan, L. N., and Li, F. (2007). Indirect calorimetry: a practical guide for clinicians. Nutr. Clin. Pract. 22, 377–388. doi: 10.1177/0115426507022004377

PubMed Abstract | CrossRef Full Text | Google Scholar

Hill, R. J., and Davies, P. S. (2001). The validity of self-reported energy intake as determined using the doubly labelled water technique. Br. J. Nutr. 85, 415–430. doi: 10.1079/BJN2000281

PubMed Abstract | CrossRef Full Text | Google Scholar

Hill, R. J., and Davies, P. S. (2002). Energy intake and energy expenditure in elite lightweight female rowers. Med. Sci. Sports Exerc. 34, 1823–1829. doi: 10.1097/00005768-200211000-00020

PubMed Abstract | CrossRef Full Text | Google Scholar

Jaeschke, L., Luzak, A., Steinbrecher, A., Jeran, S., Ferland, M., Linkohr, B., et al. (2017). 24 h-accelerometry in epidemiological studies: automated detection of non-wear time in comparison to diary information. Sci. Rep. 7:2227. doi: 10.1038/s41598-017-01092-w

PubMed Abstract | CrossRef Full Text | Google Scholar

Jakicic, J. M., Marcus, M., Gallagher, K. I., Randall, C., Thomas, E., Goss, F. L., et al. (2004). Evaluation of the sensewear pro Armband to assess energy expenditure during exercise. Med. Sci. Sports Exerc. 36, 897–904. doi: 10.1249/01.MSS.0000126805.32659.43

PubMed Abstract | CrossRef Full Text | Google Scholar

Johannsen, D. L., Calabro, M. A., Stewart, J., Franke, W., Rood, J. C., and Welk, G. J. (2010). Accuracy of armband monitors for measuring daily energy expenditure in healthy adults. Med. Sci. Sports Exerc. 42, 2134–2140. doi: 10.1249/MSS.0b013e3181e0b3ff

PubMed Abstract | CrossRef Full Text | Google Scholar

King, G. A., Torres, N., Potter, C., Brooks, T. J., and Coleman, K. J. (2004). Comparison of activity monitors to estimate energy cost of treadmill exercise. Med. Sci. Sports Exerc. 36, 1244–1251. doi: 10.1249/01.MSS.0000132379.09364.F8

PubMed Abstract | CrossRef Full Text | Google Scholar

Koehler, K., Braun, H., De Marees, M., Fusch, G., Fusch, C., Mester, J., et al. (2010). Parallel assessment of nutrition and activity in athletes: validation against doubly labelled water, 24-h urea excretion, and indirect calorimetry. J. Sports Sci. 28, 1435–1449. doi: 10.1080/02640414.2010.513482

PubMed Abstract | CrossRef Full Text | Google Scholar

Koehler, K., Braun, H., Marées, M., Fusch, G., Fusch, C., and Schaenzer, W. (2011). Assessing energy expenditure in male endurance athletes: validity of the sensewear armband. Med. Sci. Sports Exerc. 43, 1328–1333. doi: 10.1249/MSS.0b013e31820750f5

PubMed Abstract | CrossRef Full Text | Google Scholar

Koehler, K., Marees, M., Braun, H., and Schaenzer, W. (2013). Evaluation of two portable sensors for energy expenditure assessment during high-intensity running. Eur. J. Sport Sci. 13, 31–41. doi: 10.1080/17461391.2011.586439

CrossRef Full Text | Google Scholar

Kölling, S., Wiewelhove, T., Raeder, C., Endler, S., Ferrauti, A., Meyer, T., et al. (2016). Sleep monitoring of a six-day microcycle in strength and high-intensity training. Eur. J. Sport Sci. 16, 507–515. doi: 10.1080/17461391.2015.1041062

PubMed Abstract | CrossRef Full Text | Google Scholar

Loucks, A. B., Kiens, B., and Wright, H. H. (2011). Energy availability in athletes. J. Sports Sci. 29(Suppl. 1), S7–S15. doi: 10.1080/02640414.2011.588958

PubMed Abstract | CrossRef Full Text | Google Scholar

Malavolti, M., Bellentani, S., Pietrobelli, A., Tardini, L., Bellucci, A., Busacchi, M., et al. (2012). Reliability of a multisensor armband in estimating energy expenditure according to degree of obesity. J. Obes. Weight Loss Ther. 2:116. doi: 10.4172/2165-7904.1000116

CrossRef Full Text | Google Scholar

Malavolti, M., Pietrobelli, A., Dugoni, M., Poli, M., Romagnoli, E., De Cristofaro, P., et al. (2007). A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr. Metab. Cardiovasc. Dis. 17, 338–343. doi: 10.1016/j.numecd.2005.12.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Meyer, N. L., Sundgot-Borgen, J., Lohman, T. G., Ackland, T. R., Stewart, A. D., Maughan, R. J., et al. (2013). Body composition for health and performance: a survey of body composition assessment practice carried out by the ad hoc research working group on body composition, health and performance under the auspices of the IOC medical commission. Br. J. Sports Med. 47, 1044–1053. doi: 10.1136/bjsports-2013-092561

PubMed Abstract | CrossRef Full Text | Google Scholar

Mignault, D., St-Onge, M., Karelis, A. D., Allison, D. B., and Rabasa-Lhoret, R. (2005). Evaluation of the portable healthwear armband: a device to measure total daily energy expenditure in free-living type 2 diabetic individuals. Diabetes Care 28, 225–227. doi: 10.2337/diacare.28.1.225-a

PubMed Abstract | CrossRef Full Text | Google Scholar

Ndahimana, D., and Kim, E. K. (2017). Measurement methods for physical activity and energy expenditure: a review. Clin. Nutr. Res. 6, 68–80. doi: 10.7762/cnr.2017.6.2.68

PubMed Abstract | CrossRef Full Text | Google Scholar

Papazoglou, D., Augello, G., Tagliaferri, M., Savia, G., Marzullo, P., Maltezos, E., et al. (2006). Evaluation of a multisensor armband in estimating energy expenditure in obese individuals. Obesity 14, 2217–2223. doi: 10.1038/oby.2006.260

PubMed Abstract | CrossRef Full Text | Google Scholar

Patel, S. A., Benzo, R. P., Slivka, W. A., and Sciurba, F. C. (2007). Activity monitoring and energy expenditure in COPD patients: a validation study. COPD 4, 107–112. doi: 10.1080/15412550701246658

PubMed Abstract | CrossRef Full Text | Google Scholar

Reeve, M. D., Pumpa, K. L., and Ball, N. (2014). Accuracy of the sensewear armband mini and the bodymedia fit in resistance training. J. Sci. Med. Sport 17, 630–634. doi: 10.1016/j.jsams.2013.08.007

PubMed Abstract | CrossRef Full Text | Google Scholar

Riou, M. È., Rioux, F., Lamothe, G., and Doucet, É. (2015). Validation and reliability of a classification method to measure the time spent performing different activities. PLoS ONE 10:e0128299. doi: 10.1371/journal.pone.0128299

PubMed Abstract | CrossRef Full Text | Google Scholar

Sjödin, A. M., Andersson, A. B., Högberg, J. M., and Westerterp, K. R. (1994). Energy balance in cross-country skiers: a study using doubly labeled water. Med. Sci. Sports Exerc. 26, 720–724. doi: 10.1249/00005768-199406000-00011

PubMed Abstract | CrossRef Full Text

St-Onge, M., Mignault, D., Allison, D. B., and Rabasa-Lhoret, R. (2007). Evaluation of a portable device to measure daily energy expenditure in free-living adults. Am. J. Clin. Nutr. 85, 742–749.

PubMed Abstract | Google Scholar

Taylor, M. (2012). Validation of the BodyMedia Mini Armband to Estimate Energy Expenditure of Female Basketball Players during Variable Intensity Game-Like Conditions. Ph.D., University of Pittsburgh.

Trappe, T. A., Gastaldelli, A., Jozsi, A. C., Troup, J. P., and Wolfe, R. R. (1997). Energy expenditure of swimmers during high volume training. Med. Sci. Sports Exerc. 29, 950–954. doi: 10.1097/00005768-199707000-00015

PubMed Abstract | CrossRef Full Text | Google Scholar

Vanheest, J. L., Rodgers, C. D., Mahoney, C. E., and De Souza, M. J. (2013). Ovarian suppression impairs sport performance in junior elite female swimmers. Med. Sci. Sports Exerc. 46, 156–166. doi: 10.1249/MSS.0b013e3182a32b72

PubMed Abstract | CrossRef Full Text | Google Scholar

Van Hoye, K., Boen, F., and Lefevre, J. (2015). Validation of the sensewear armband in different ambient temperatures. J. Sports Sci. 33, 1007–1018. doi: 10.1080/02640414.2014.981846

PubMed Abstract | CrossRef Full Text | Google Scholar

van Hoye, K., Mortelmans, P., and Lefevre, J. (2014). Validation of the sensewear pro3 armband using an incremental exercise test. J. Strength Cond. Res. 28, 2806–2814. doi: 10.1519/JSC.0b013e3182a1f836

PubMed Abstract | CrossRef Full Text | Google Scholar

Vernillo, G., Savoldelli, A., Pellegrini, B., and Schena, F. (2015). Validity of the sensewear armband to assess energy expenditure in graded walking. J. Phys. Act. Health 12, 178–183. doi: 10.1123/jpah.2013-0437

PubMed Abstract | CrossRef Full Text | Google Scholar

Walker, E. J., McAinch, A. J., Sweeting, A., and Aughey, R. J. (2016). Inertial sensors to estimate the energy expenditure of team-sport athletes. J. Sci. Med. Sport 19, 177–181. doi: 10.1016/j.jsams.2015.01.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Welk, G. J., McClain, J. J., Eisenmann, J. C., and Wickel, E. E. (2007). Field validation of the MTI actigraph and bodymedia armband monitor using the IDEEA monitor. Obesity 15, 918–928. doi: 10.1038/oby.2007.624

PubMed Abstract | CrossRef Full Text | Google Scholar

Welk, G., Kim, Y., Shook, R. P., Ellingson, L., and Lobelo, R. L. (2017). Validation of a noninvasive, disposable activity monitor for clinical applications. J. Phys. Act. Health 14, 546–551. doi: 10.1123/jpah.2016-0003

PubMed Abstract | CrossRef Full Text | Google Scholar

Westerterp, K. R. (2001). Limits to sustainable human metabolic rate. J. Exp. Biol. 204(Pt 18), 3183–3187.

PubMed Abstract | Google Scholar

Westerterp, K. R. (2013). Physical activity and physical activity induced energy expenditure in humans: measurement, determinants, and effects. Front. Physiol. 4:90. doi: 10.3389/fphys.2013.00090

PubMed Abstract | CrossRef Full Text | Google Scholar

Westerterp, K. R., Saris, W. H., van Es, M., and ten Hoor, F. (1986). Use of the doubly labeled water technique in humans during heavy sustained exercise. J. Appl. Physiol. 61, 2162–2167.

PubMed Abstract | Google Scholar

Woodruff, S. J., and Meloche, R. D. (2013). Energy availability of female varsity volleyball players. Int. J. Sport Nutr. Exerc. Metab. 23, 24–30. doi: 10.1123/ijsnem.23.1.24

PubMed Abstract | CrossRef Full Text | Google Scholar

Zanetti, S., Pumpa, K. L., Wheeler, K. W., and Pyne, D. B. (2014). Validity of the sensewear armband to assess energy expenditure during intermittent exercise and recovery in rugby union players. J. Strength Cond. Res. 28, 1090–1095. doi: 10.1519/JSC.0000000000000243

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: accelerometry, energy balance, high-intensity exercise, resistance exercise, measurement error

Citation: Koehler K and Drenowatz C (2017) Monitoring Energy Expenditure Using a Multi-Sensor Device—Applications and Limitations of the SenseWear Armband in Athletic Populations. Front. Physiol. 8:983. doi: 10.3389/fphys.2017.00983

Received: 27 September 2017; Accepted: 17 November 2017;
Published: 30 November 2017.

Edited by:

Billy Sperlich, Universität Würzburg, Germany

Reviewed by:

Salvatore Tedesco, University College Cork, Ireland
Beat Knechtle, University of Zurich, Switzerland

Copyright © 2017 Koehler and Drenowatz. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Karsten Koehler, kkoehler3@unl.edu

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.